The DOI matches its Crossref record.
Hybridization Enhancement Using Cavitation Microstreaming
Abstract
Conventional DNA microarray hybridization relies on diffusion of target to surface-bound probes, and thus is a rate-limited process. In this paper, a micromixing technique based on cavitation microstreaming principle that was developed to accelerate hybridization process is explained. Fluidic experiments showed that air bubbles resting on a solid surface and set into vibration by a sound field generated steady circulatory flows, resulting in global convection flows and, thus, rapid mixing. The time to fully mix dyed solutions in a 50-microL chamber using cavitation microstreaming was significantly reduced from hours (a pure diffusion-based mixing) to 6 s. Cavitation microstreaming was implemented to enhance DNA hybridization in both fluorescence-detection-based and electrochemical-detection-based DNA microarray chips. The former showed that cavitation microstreaming results in up to 5-fold hybridization signal enhancement with significantly improved signal uniformity, as compared to the results obtained in conventional diffusion-based biochips for a given time (2 h). Hybridization kinetics study in the electrochemical detection-based chips showed that acoustic microstreaming results in up to 5-fold kinetics acceleration. Acoustic microstreaming has many advantages over most existing techniques used for hybridization enhancement, including a simple apparatus, ease of implementation, low power consumption (approximately 2 mW), and low cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198
Micromixers—a review on passive and active mixing principles
Hessel, V., Löwe, H., & Schönfeld, F. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2004.11.033 · Cited by 1,479
Lee, C.-Y., Chang, C.-L., Wang, Y.-N., & Fu, L.-M. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12053263 · Cited by 1,111
Microscale acoustofluidics: Microfluidics driven via acoustics and ultrasonics
Friend, J., & Yeo, L. Y. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.647 · Cited by 964
Cai, G., Xue, L., Zhang, H., & Lin, J. (2017) · Micromachines · doi:10.3390/mi8090274 · Cited by 467
Micromixing Within Microfluidic Devices
Capretto, L., Cheng, W., Hill, M., & Zhang, X. (2011) · Topics in Current Chemistry · doi:10.1007/128_2011_150 · Cited by 448
APPLICATIONS OF DNA MICROARRAYS IN BIOLOGY
Stoughton, R. B. (2005) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.74.082803.133212 · Cited by 390
Micropumps, microvalves, and micromixers within PCR microfluidic chips: Advances and trends
Zhang, C., Xing, D., & Li, Y. (2007) · Biotechnology Advances · doi:10.1016/j.biotechadv.2007.05.003 · Cited by 376
Ultrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Metadata
- Authors
- Liu, R. H., Lenigk, R., Druyor-Sanchez, R. L., Yang, J., & Grodzinski, P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-03-05
- Volume
- 75
- Issue
- 8
- Pages
- 1911-1917
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2068910188
- Cited by
- 244
- References
- 0
- FWCI
- 14.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.