The DOI matches its Crossref record.
Photonic Crystal Aqueous Metal Cation Sensing Materials
Abstract
We developed a polymerized crystalline colloidal array photonic material that senses metal cations in water at low concentrations (PCCACS). Metal cations such as Cu 2+, Co 2+, Ni 2+, and Zn 2+ bind to 8-hydroxyquinoline groups covalently attached to the PCCACS. At low metal concentrations (<μM), the cations form bisliganded complexes with two 8-hydroxyquinolines that cross-link the hydrogel and cause it to shrink, which blue shifts the photonic crystal diffraction. These bisliganded cross-links break at higher cation concentrations due to the formation of monoliganded cation complexes. This red shifts the diffraction. We have extended hydrogel volume phase transition theory in order to quantitatively model the diffraction dependence upon metal concentration. These materials can be used as a dosimeter to sense extremely low metal cation concentrations or as a sensor material for concentrations greater than 1 μM. Metal cation concentrations can be determined visually from the color of the diffracted light or can be determined by reflectance measurements using a spectrophotometer. This sensing material could be used in the field to visually determine metal cation concentrations in drinking water. A color chart would be used to relate the diffracted color to the metal cation concentration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Synthetic Molecular Motors and Mechanical Machines
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200504313 · Cited by 2,609
Erbas-Cakmak, S., Leigh, D. A., McTernan, C. T., & Nussbaumer, A. L. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00146 · Cited by 1,982
Materials Aspects of Photonic Crystals
López, C. (2003) · Advanced Materials · doi:10.1002/adma.200300386 · Cited by 977
Photonic Crystals for Chemical Sensing and Biosensing
Fenzl, C., Hirsch, T., & Wolfbeis, O. S. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201307828 · Cited by 884
Synthetische molekulare Motoren und mechanische Maschinen
Kay, E. R., Leigh, D. A., & Zerbetto, F. (2007) · Angewandte Chemie · doi:10.1002/ange.200504313 · Cited by 624
Highly Tunable Superparamagnetic Colloidal Photonic Crystals
Ge, J., Hu, Y., & Yin, Y. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200701992 · Cited by 558
Magnetically Tunable Colloidal Photonic Structures in Alkanol Solutions
Ge, J., & Yin, Y. (2008) · Advanced Materials · doi:10.1002/adma.200800657 · Cited by 317
A General Photonic Crystal Sensing Motif: Creatinine in Bodily Fluids
Sharma, A. C., Jana, T., Kesavamoorthy, R., Shi, L., Virji, M. A., Finegold, D. N., & Asher, S. A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja038187s · Cited by 304
Self-citationNon-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Photonic Crystals in Bioassays
Zhao, Y., Zhao, X., & Gu, Z. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201000098 · Cited by 255
Two-Dimensional Photonic Crystal Chemical and Biomolecular Sensors
Cai, Z., Smith, N. L., Zhang, J.-T., & Asher, S. A. (2015) · Analytical Chemistry · doi:10.1021/ac504679n · Cited by 216
Self-citation
Metadata
- Authors
- Asher, S. A., Sharma, A. C., Goponenko, A. V., & Ward, M. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-02-27
- Volume
- 75
- Issue
- 7
- Pages
- 1676-1683
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1964274826
- Cited by
- 161
- References
- 0
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.