Capillary Electrophoresis to Mass Spectrometry Interface Using a Porous Junction
The DOI matches its Crossref record.
Abstract
A new capillary electrophoresis interface to electrospray ionization mass spectrometry (CE/ESI-MS) is introduced in which the electrical connection to the CE capillary outlet/ESI electrode is achieved by transfer of small ions related to the background electrolyte (BGE) through a porous section near the CE capillary outlet. In this design, only a small section of the capillary wall is made porous. The porous section is created by first thinning a small section of the capillary wall by drilling a well into it and then etching the remaining thin wall porous. This design has two advantages over previous designs (in which the whole circumference of the capillary was made porous): first, the capillary interface is more robust because only a small section of it is made porous, and therefore, no liquid junction is needed to secure the porous section. The electrical connection is achieved simply by inserting the capillary outlet containing the porous junction into the existing ESI needle and filling the needle with the BGE. Second, the time required to make the fused silica porous is reduced from approximately 1 h to a few minutes. In addition, there is no dead volume associated with the porous design, and because the actual metal/liquid contact occurs outside of the CE capillary, bubble formation due to redox reactions of water at the electrode does not affect CE/ESI-MS performance. The performance of this interface is demonstrated by the analyses of peptide and protein mixtures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Moini, M. (2007) · Analytical Chemistry · doi:10.1021/ac0704560 · Cited by 322
Self-citationCapillary electrophoresis–mass spectrometry for the analysis of intact proteins
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.048 · Cited by 185
Wang, Y., Fonslow, B. R., Wong, C. C. L., Nakorchevsky, A., & Yates, J. R. (2012) · Analytical Chemistry · doi:10.1021/ac301091m · Cited by 144
Belov, A. M., Viner, R., Santos, M. R., Horn, D. M., Bern, M., Karger, B. L., & Ivanov, A. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1781-1 · Cited by 97
“The CESI interface enabled the online integration of high resolution CZE separations with MS conducted at ultra-low flow rates (measured at 10–20 nL/min) and without analyte dilution prior to ionization [33, 46].”
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
Metadata
- Authors
- Whitt, J. T., & Moini, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-04-03
- Volume
- 75
- Issue
- 9
- Pages
- 2188-2191
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1978583538
- Cited by
- 74
- References
- 0
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capillary Electrophoresis to Mass Spectrometry Interface Using a Porous Junction. https://app.cochat.ai/papers/10.1021/ac026380j
- The paper
- Whitt, J. T., & Moini, M. (2003). Capillary Electrophoresis to Mass Spectrometry Interface Using a Porous Junction. Analytical Chemistry. https://doi.org/10.1021/ac026380j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.