Capillary electrophoresis–mass spectrometry for the analysis of intact proteins
Abstract
Developments in the fields of protein chemistry, proteomics and biotechnology have increased the demand for suitable analytical techniques for the analysis of intact proteins. In 1989, capillary electrophoresis (CE) was combined with mass spectrometry (MS) for the first time and its potential usefulness for the analysis of intact (i.e. non-digested) proteins was shown. This article provides an overview of the applications of CE-MS within the field of intact protein analysis. The principles of the applied CE modes and ionization techniques used for CE-MS of intact proteins are shortly described. It is shown that separations are predominantly carried out by capillary zone electrophoresis and capillary isoelectric focusing, whereas electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) are the most popular ionization techniques used for interfacing. The combination of CE with inductively coupled plasma (ICP) MS for the analysis of metalloproteins is also discussed. The various CE-MS combinations are systematically outlined and tables provide extensive overviews of the applications of each technique for intact protein analysis. Selected examples are given to illustrate the usefulness of the CE-MS techniques. Examples include protein isoform assignment, single cell analysis, metalloprotein characterization, proteomics and biomarker screening. Finally, chip-based electrophoresis combined with MS is shortly treated and some of its applications are described. It is concluded that CE-MS represents a powerful tool for the analysis of intact proteins yielding unique separations and information.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
CZE is particularly attractive for protein analysis because proteins have small diffusion coefficients.
“This is particularly attractive for protein analysis because they have small diffusion coefficients28,29.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [29]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cited by
Sorted by citations
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507 · see citing works
“CZE has been the most common CE mode applied to the mass spectrometry of intact proteins [59].”
MethodMischak, H., Coon, J. J., Novak, J., Weissinger, E. M., Schanstra, J. P., & Dominiczak, A. F. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20205 · Cited by 193 · see citing works
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · Analytical Chemistry · doi:10.1021/ac303158f · Cited by 149 · see citing works
Self-citationRecent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112 · see citing works
<scp>CE</scp>‐<scp>MS</scp> for the analysis of intact proteins 2010–2012
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · ELECTROPHORESIS · doi:10.1002/elps.201200439 · Cited by 96 · see citing works
Self-citationCapillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92 · see citing works
CE–MS for proteomics: Advances in interface development and application
Ramautar, R., Heemskerk, A. A. M., Hensbergen, P. J., Deelder, A. M., Busnel, J.-M., & Mayboroda, O. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.050 · Cited by 86 · see citing works
CE–ESI‐MS for bottom‐up proteomics: Advances in separation, interfacing and applications
Heemskerk, A. A. M., Deelder, A. M., & Mayboroda, O. A. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21432 · Cited by 61 · see citing works
Nguyen, T. T. T. N., Petersen, N. J., & Rand, K. D. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.07.002 · Cited by 33 · see citing works
Bertoletti, L., Schappler, J., Colombo, R., Rudaz, S., Haselberg, R., Domínguez-Vega, E., Raimondi, S., Somsen, G. W., & De Lorenzi, E. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.10.010 · Cited by 25 · see citing works
Self-citation
- Authors
- Haselberg, R., de Jong, G. J., & Somsen, G. W.
- Affiliations
- Utrecht University (NL)
- Corresponding author
- Haselberg, Rob
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2007-08
- Volume
- 1159
- Issue
- 1-2
- Pages
- 81-109
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2087101979
- Cited by
- 185
- References
- 0
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 3 · 2023: 5 · 2022: 5 · 2021: 3 · 2020: 3 · 2019: 10 · 2018: 9 · 2017: 8 · 2016: 8 · 2015: 7 · 2014: 17 · 2013: 14 · 2012: 16
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Chromatography A (publishedVersion)
- PubMed (publishedVersion)
- VU Research Portal (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- capillary electrophoresis-mass spectrometry, top-down proteomics, capillary zone electrophoresis, capillary isoelectric focusing, electrospray ionization, MALDI, inductively coupled plasma mass spectrometry, single-cell analysis, proteomics, biomarker screening
- MeSH terms
- Buffers, Isoelectric Focusing, Metalloproteins, Proteins, Sensitivity and Specificity, Spectrophotometry, Atomic, Reproducibility of Results, Biomarkers, Protein Folding, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Electrophoresis, Capillary, Protein Isoforms, Coated Materials, Biocompatible, Spectrometry, Mass, Electrospray Ionization, Proteomics, Capillary Electrochromatography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review