The DOI matches its Crossref record.
Flow Control Valves for Analytical Microfluidic Chips without Mechanical Parts Based on Thermally Responsive Monolithic Polymers
Abstract
Monolithic plugs of poly(N-isopropylacrylamide) cross-linked with 5% methylenebisacrylamide have been prepared by photoinitiated polymerization within the channel of a microfluidic device. The volume change associated with the polymer phase transition at its lower critical solution temperature of 32 degrees C allows both the rapid swelling and the deswelling of the monoliths enabling the polymer to close or open the channel as it functions as a nonmechanical valve. Thermoelectric elements capable of changing the temperature of the system between 17 and 57 degrees C were used to actuate the valve. Flow through the device was monitored by fluorescence measurements via the laser-triggered photobleaching of a dye contained in the liquid phase. Photobleaching occurs quickly once the flow is stopped, and the time required to open and close the valve was 3.5 and 5.0 s, respectively. No changes in function were observed even after 120 open-close cycles. Although the 2-mm-long valve was prepared from a polymerization mixture consisting of only a 5% aqueous solution of monomers, it resists pressures of up to 1.38 MPa (200 psi) without observable structural damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
Smart polymers: Physical forms and bioengineering applications
Kumar, A., Srivastava, A., Galaev, I. Y., & Mattiasson, B. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.003 · Cited by 742
Review on Hydrogel-based pH Sensors and Microsensors
Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., & Adler, H.-J. P. (2008) · Sensors · doi:10.3390/s8010561 · Cited by 742
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Metadata
- Authors
- Yu, C., Mutlu, S., Selvaganapathy, P., Mastrangelo, C. H., Svec, F., & Fréchet, J. M. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-03-14
- Volume
- 75
- Issue
- 8
- Pages
- 1958-1961
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1974743608
- Cited by
- 202
- References
- 0
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flow Control Valves for Analytical Microfluidic Chips without Mechanical Parts Based on Thermally Responsive Monolithic Polymers. https://app.cochat.ai/papers/10.1021/ac026455j
- The paper
- Yu, C., Mutlu, S., Selvaganapathy, P., Mastrangelo, C. H., Svec, F., & Fréchet, J. M. J. (2003). Flow Control Valves for Analytical Microfluidic Chips without Mechanical Parts Based on Thermally Responsive Monolithic Polymers. Analytical Chemistry. https://doi.org/10.1021/ac026455j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.