The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Review on Hydrogel-based pH Sensors and Microsensors
Open accessAbstract
Stimuli-responsive hydrogels are materials with great potential for development of active functionalities in fluidics and micro-fluidics. Based on the current state of research on pH sensors, hydrogel sensors are described qualitatively and quantitatively for the first time. The review introduces the physical background of the special properties of stimuli-responsive hydrogels. Following, transducers are described which are able to convert the non-electrical changes of the physical properties of stimuli-responsive hydrogels into an electrical signal. Finally, the specific sensor properties, design rules and general conditions for sensor applications are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermodynamics of High Polymer Solutions
Flory, P. J. (1942) · The Journal of Chemical Physics · doi:10.1063/1.1723621 · Cited by 4,374
Statistical Mechanics of Cross-Linked Polymer Networks II. Swelling
Flory, P. J., & Rehner, J. (1943) · The Journal of Chemical Physics · doi:10.1063/1.1723792 · Cited by 3,865
Statistical Mechanics of Cross-Linked Polymer Networks I. Rubberlike Elasticity
Flory, P. J., & Rehner, J. (1943) · The Journal of Chemical Physics · doi:10.1063/1.1723791 · Cited by 2,421
Polymerized colloidal crystal hydrogel films as intelligent chemical sensing materials
Holtz, J. H., & Asher, S. A. (1997) · Nature · doi:10.1038/39834 · Cited by 2,004
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Solutions of Long Chain Compounds
Huggins, M. L. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750930 · Cited by 1,919
Tanaka, T., & Fillmore, D. J. (1979) · The Journal of Chemical Physics · doi:10.1063/1.437602 · Cited by 1,626
Collapse of Gels and the Critical Endpoint
Tanaka, T. (1978) · Physical Review Letters · doi:10.1103/physrevlett.40.820 · Cited by 1,581
Thermodynamics of High Polymer Solutions
Flory, P. J. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750971 · Cited by 1,447
Collapse of Gels in an Electric Field
Tanaka, T., Nishio, I., Sun, S.-T., & Ueno-Nishio, S. (1982) · Science · doi:10.1126/science.218.4571.467 · Cited by 1,296
Cited by
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Design and applications of interpenetrating polymer network hydrogels. A review
Dragan, E. S. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.01.065 · Cited by 992
Fiber-Optic Chemical Sensors and Biosensors (2015–2019)
Wang, X.-D., & Wolfbeis, O. S. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04708 · Cited by 833
Liang, H., Guan, Q., Chen, L., Zhu, Z., Zhang, W., & Yu, S. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200710 · Cited by 673
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Metadata
- Authors
- Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., & Adler, H.-J. P.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2008-01-25
- Volume
- 8
- Issue
- 1
- Pages
- 561-581
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2115644711
- Cited by
- 742
- References
- 54
- FWCI
- 12.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review on Hydrogel-based pH Sensors and Microsensors. https://app.cochat.ai/papers/10.3390/s8010561
- The paper
- Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., & Adler, H.-J. P. (2008). Review on Hydrogel-based pH Sensors and Microsensors. Sensors. https://doi.org/10.3390/s8010561
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.