The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quantification of Proteins and Metabolites by Mass Spectrometry without Isotopic Labeling or Spiked Standards
Abstract
A new method is presented for quantifying proteomic and metabolomic profile data by liquid chromatography-mass spectrometry (LC-MS) with electrospray ionization. This biotechnology provides differential expression measurements and enables the discovery of biological markers (biomarkers). Work presented here uses human serum but is applicable to any fluid or tissue. The approach relies on linearity of signal versus molecular concentration and reproducibility of sample processing. There is no use of isotopic labeling or chemically similar standard materials. Linear standard curves are reported for a variety of compounds introduced into human serum. As a measure of analytical reproducibility for proteome and metabolome sampling, median coefficients of variation of 25.7 and 23.8%, respectively, were determined for approximately 3400 molecular ions (not counting their numerous isotopes) from 25 independently processed human serum samples, corresponding to a total of 85000 individual molecular ion measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Dynamic Programming Algorithm Optimization for Spoken Word Recognition
Sakoe, H., & Chiba, S. (1978) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1978.1163055 · Cited by 6,727
Cited by
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Absolute Quantification of Proteins by LCMSE
Silva, J. C., Gorenstein, M. V., Li, G.-Z., Vissers, J. P. C., & Geromanos, S. J. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500230-mcp200 · Cited by 1,529
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Peterson, A. C., Russell, J. D., Bailey, D. J., Westphall, M. S., & Coon, J. J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.020131 · Cited by 1,288
Comparison of Label-free Methods for Quantifying Human Proteins by Shotgun Proteomics
Old, W. M., Meyer-Arendt, K., Aveline-Wolf, L., Pierce, K. G., Mendoza, A., Sevinsky, J. R., Resing, K. A., & Ahn, N. G. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500084-mcp200 · Cited by 1,206
Metadata
- Authors
- Wang, W., Zhou, H., Lin, H., Roy, S., Shaler, T. A., Hill, L. R., Norton, S., Kumar, P., Anderle, M., & Becker, C. H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-08-08
- Volume
- 75
- Issue
- 18
- Pages
- 4818-4826
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2152180036
- Cited by
- 653
- References
- 2
- FWCI
- 14.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantification of Proteins and Metabolites by Mass Spectrometry without Isotopic Labeling or Spiked Standards. https://app.cochat.ai/papers/10.1021/ac026468x
- The paper
- Wang, W., Zhou, H., Lin, H., Roy, S., Shaler, T. A., Hill, L. R., Norton, S., Kumar, P., Anderle, M., & Becker, C. H. (2003). Quantification of Proteins and Metabolites by Mass Spectrometry without Isotopic Labeling or Spiked Standards. Analytical Chemistry. https://doi.org/10.1021/ac026468x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.