The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quantification of Proteins and Metabolites by Mass Spectrometry without Isotopic Labeling or Spiked Standards
Abstract
A new method is presented for quantifying proteomic and metabolomic profile data by liquid chromatography-mass spectrometry (LC-MS) with electrospray ionization. This biotechnology provides differential expression measurements and enables the discovery of biological markers (biomarkers). Work presented here uses human serum but is applicable to any fluid or tissue. The approach relies on linearity of signal versus molecular concentration and reproducibility of sample processing. There is no use of isotopic labeling or chemically similar standard materials. Linear standard curves are reported for a variety of compounds introduced into human serum. As a measure of analytical reproducibility for proteome and metabolome sampling, median coefficients of variation of 25.7 and 23.8%, respectively, were determined for approximately 3400 molecular ions (not counting their numerous isotopes) from 25 independently processed human serum samples, corresponding to a total of 85000 individual molecular ion measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Dynamic Programming Algorithm Optimization for Spoken Word Recognition
Sakoe, H., & Chiba, S. (1978) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1978.1163055 · Cited by 6,727
Cited by
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Absolute Quantification of Proteins by LCMSE
Silva, J. C., Gorenstein, M. V., Li, G.-Z., Vissers, J. P. C., & Geromanos, S. J. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500230-mcp200 · Cited by 1,529
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Peterson, A. C., Russell, J. D., Bailey, D. J., Westphall, M. S., & Coon, J. J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.020131 · Cited by 1,288
Comparison of Label-free Methods for Quantifying Human Proteins by Shotgun Proteomics
Old, W. M., Meyer-Arendt, K., Aveline-Wolf, L., Pierce, K. G., Mendoza, A., Sevinsky, J. R., Resing, K. A., & Ahn, N. G. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500084-mcp200 · Cited by 1,206
Interpretation of Shotgun Proteomic Data
Nesvizhskii, A. I., & Aebersold, R. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r500012-mcp200 · Cited by 1,025
Keshishian, H., Addona, T., Burgess, M., Kuhn, E., & Carr, S. A. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700354-mcp200 · Cited by 684
Zhou, B., Xiao, J. F., Tuli, L., & Ressom, H. W. (2011) · Molecular BioSystems · doi:10.1039/c1mb05350g · Cited by 639
Mass Spectrometry-Based Label-Free Quantitative Proteomics
Zhu, W., Smith, J. W., & Huang, C.-M. (2010) · Journal of Biomedicine and Biotechnology · doi:10.1155/2010/840518 · Cited by 629
Data processing for mass spectrometry-based metabolomics
Katajamaa, M., & Orešič, M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.021 · Cited by 616
Identification of Proteins in Human Cytomegalovirus (HCMV) Particles: the HCMV Proteome
Varnum, S. M., Streblow, D. N., Monroe, M. E., Smith, P., Auberry, K. J., Paša-Tolić, L., Wang, D., Camp, D. G., Rodland, K., Wiley, S., et al. (2004) · Journal of Virology · doi:10.1128/jvi.78.20.10960-10966.2004 · Cited by 598
Bajad, S. U., Lu, W., Kimball, E. H., Yuan, J., Peterson, C., & Rabinowitz, J. D. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.019 · Cited by 592
Rauniyar, N. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms161226120 · Cited by 406
“The data obtained by a label-free targeted method can be normalized using peptides from housekeeping proteins whose abundance do not change from sample to sample [58].”
BackgroundMethodInfluentialapLCMS—adaptive processing of high-resolution LC/MS data
Yu, T., Park, Y., Johnson, J. M., & Jones, D. P. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp291 · Cited by 406
Processing methods for differential analysis of LC/MS profile data
Katajamaa, M., & Orešič, M. (2005) · BMC Bioinformatics · doi:10.1186/1471-2105-6-179 · Cited by 400
Genetic basis of proteome variation in yeast
Foss, E. J., Radulovic, D., Shaffer, S. A., Ruderfer, D. M., Bedalov, A., Goodlett, D. R., & Kruglyak, L. (2007) · Nature Genetics · doi:10.1038/ng.2007.22 · Cited by 358
Normalization method for metabolomics data using optimal selection of multiple internal standards
Sysi-Aho, M., Katajamaa, M., Yetukuri, L., & Orešič, M. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-93 · Cited by 358
Gorrochategui, E., Jaumot, J., Lacorte, S., & Tauler, R. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.07.004 · Cited by 352
Normalization strategies for metabonomic analysis of urine samples
Warrack, B. M., Hnatyshyn, S., Ott, K.-H., Reily, M. D., Sanders, M., Zhang, H., & Drexler, D. M. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.01.007 · Cited by 332
Zhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
bioinformatics tools for mass spectroscopy-based metabolomic data processing and analysis
Sugimoto, M., Kawakami, M., Robert, M., Soga, T., & Tomita, M. (2012) · Current Bioinformatics · doi:10.2174/157489312799304431 · Cited by 307
Clinical proteomics: A need to define the field and to begin to set adequate standards
Mischak, H., Apweiler, R., Banks, R. E., Conaway, M., Coon, J., Dominiczak, A., Ehrich, J. H. H., Fliser, D., Girolami, M., Hermjakob, H., et al. (2007) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.200600771 · Cited by 307
Chemometric methods in data processing of mass spectrometry-based metabolomics: A review
Yi, L., Dong, N., Yun, Y., Deng, B., Ren, D., Liu, S., & Liang, Y. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.02.001 · Cited by 305
A Review on Quantitative Multiplexed Proteomics
Pappireddi, N., Martin, L., & Wühr, M. (2019) · ChemBioChem · doi:10.1002/cbic.201800650 · Cited by 299
Burkhart, J. M., Schumbrutzki, C., Wortelkamp, S., Sickmann, A., & Zahedi, R. P. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2011.11.016 · Cited by 297
Advances in Urinary Proteome Analysis and Biomarker Discovery
Fliser, D., Novak, J., Thongboonkerd, V., Argile[Combining Acute Accent]s, A. G. A., Jankowski, V., Girolami, M. A., Jankowski, J., & Mischak, H. (2007) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006090956 · Cited by 286
Corbett, B. A., Kantor, A. B., Schulman, H., Walker, W. L., Lit, L., Ashwood, P., Rocke, D. M., & Sharp, F. R. (2007) · Molecular Psychiatry · doi:10.1038/sj.mp.4001943 · Cited by 197
A statistical framework for protein quantitation in bottom-up MS-based proteomics
Karpievitch, Y., Stanley, J., Taverner, T., Huang, J., Adkins, J. N., Ansong, C., Heffron, F., Metz, T. O., Qian, W.-J., Yoon, H., et al. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp362 · Cited by 176
Deconvolution and Database Search of Complex Tandem Mass Spectra of Intact Proteins
Liu, X., Inbar, Y., Dorrestein, P. C., Wynne, C., Edwards, N., Souda, P., Whitelegge, J. P., Bafna, V., & Pevzner, P. A. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.002766 · Cited by 170
Mazur, M. T., Cardasis, H. L., Spellman, D. S., Liaw, A., Yates, N. A., & Hendrickson, R. C. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910776107 · Cited by 87
Rodríguez-Suárez, E., Gonzalez, E., Hughes, C., Conde-Vancells, J., Rudella, A., Royo, F., Palomo, L., Elortza, F., Lu, S. C., Mato, J. M., et al. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2014.04.008 · Cited by 76
Mixed-effects statistical model for comparative LC–MS proteomics studies
Daly, D. S., Anderson, K. K., Panisko, E. A., Purvine, S. O., Fang, R., Monroe, M. E., & Baker, S. E. (2008) · Journal of Proteome Research · doi:10.1021/pr070441i · Cited by 50
Armstrong, C. T., Anderson, J. L. R., & Denton, R. M. (2014) · Biochemical Journal · doi:10.1042/bj20131664 · Cited by 44
Drzewicka, K., Głuchowska, K. M., Mlącki, M., Hofman, B., Tuszyńska, I., Ryan, T. A. J., Piwowar, K., Wilczyński, B., Dymkowska, D., Grzybowski, M. M., et al. (2025) · Frontiers in Immunology · doi:10.3389/fimmu.2025.1544973 · Cited by 3
Metadata
- Authors
- Wang, W., Zhou, H., Lin, H., Roy, S., Shaler, T. A., Hill, L. R., Norton, S., Kumar, P., Anderle, M., & Becker, C. H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-08-08
- Volume
- 75
- Issue
- 18
- Pages
- 4818-4826
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2152180036
- Cited by
- 653
- References
- 2
- FWCI
- 14.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.