Development of High-Sensitivity Ion Trap Ion Mobility Spectrometry Time-of-Flight Techniques: A High-Throughput Nano-LC-IMS-TOF Separation of Peptides Arising from a Drosophila Protein Extract
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A linear octopole trap interface for an ion mobility time-of-flight mass spectrometer has been developed for focusing and accumulating continuous beams of ions produced by electrospray ionization. The interface improves experimental efficiencies by factors of approximately 50-200 compared with an analogous configuration that utilizes a three-dimensional Paul geometry trap (Hoaglund-Hyzer, C. S.; Lee, Y. J.; Counterman, A. E.; Clemmer, D. E. Anal. Chem. 2002, 74, 992-1006). With these improvements, it is possible to record nested drift (flight) time distributions for complex mixtures in fractions of a second. We demonstrate the approach for several well-defined peptide mixtures and an assessment of the detection limits is given. Additionally, we demonstrate the utility of the approach in the field of proteomics by an on-line, three-dimensional nano-LC-ion mobility-TOF separation of tryptic peptides from the Drosophila proteome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Ecdysone receptors and their biological actions
Riddiford, L. M., Cherbas, P., & Truman, J. W. (2000) · Vitamins & Hormones · doi:10.1016/s0083-6729(00)60016-x · Cited by 605
Self-citation
Cited by
Pringle, S. D., Giles, K., Wildgoose, J. L., Williams, J. P., Slade, S. E., Thalassinos, K., Bateman, R. H., Bowers, M. T., & Scrivens, J. H. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.07.021 · Cited by 808
Lapthorn, C., Pullen, F., & Chowdhry, B. Z. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21349 · Cited by 398
Ion Mobility Spectrometry: Principles and Applications
Borsdorf, H., & Eiceman, G. A. (2006) · Applied Spectroscopy Reviews · doi:10.1080/05704920600663469 · Cited by 395
Jurneczko, E., & Barran, P. E. (2011) · The Analyst · doi:10.1039/c0an00373e · Cited by 328
Multiplexed MS/MS for improved data-independent acquisition
Egertson, J. D., Kuehn, A., Merrihew, G. E., Bateman, N. W., MacLean, B. X., Ting, Y. S., Canterbury, J. D., Marsh, D. M., Kellmann, M., Zabrouskov, V., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2528 · Cited by 304
Koeniger, S. L., Merenbloom, S. I., Valentine, S. J., Jarrold, M. F., Udseth, H. R., Smith, R. D., & Clemmer, D. E. (2006) · Analytical Chemistry · doi:10.1021/ac051060w · Cited by 272
Self-citationSerine Octamers: Cluster Formation, Reactions, and Implications for Biomolecule Homochirality
Nanita, S. C., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200501328 · Cited by 184
Spontaneous Anti-Resolution in Heterochiral Clusters of Serine
Julian, R. R., Myung, S., & Clemmer, D. E. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031516w · Cited by 42
Self-citationCrowgey, E. L., Matlock, A., Venkatraman, V., Fert-Bober, J., & Van Eyk, J. E. (2017) · Methods in Molecular Biology · doi:10.1007/978-1-4939-6783-4_19 · Cited by 9
Metadata
- Authors
- Myung, S., Lee, Y. J., Moon, M. H., Taraszka, J., Sowell, R., Koeniger, S., Hilderbrand, A. E., Valentine, S. J., Cherbas, L., Cherbas, P., Kaufmann, T. C., Miller, D. F., Mechref, Y., Novotny, M. V., Ewing, M. A., Sporleder, C. R., & Clemmer, D. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-08-23
- Volume
- 75
- Issue
- 19
- Pages
- 5137-5145
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1982282366
- Cited by
- 112
- References
- 2
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.