The DOI matches its Crossref record.
2,5-Dihydroxybenzoic Acid Butylamine and Other Ionic Liquid Matrixes for Enhanced MALDI-MS Analysis of Biomolecules
Abstract
The performance of the new ionic liquid MALDI-MS matrix 2,5-dihydroxybenzoic acid butylamine (DHBB) was assessed and compared to results obtained with the ionic liquid MALDI-MS matrixes alpha-cyano-4-hydroxycinnamic acid butylamine (CHCAB), 3,5-dimethoxycinnamic acid triethylamine (SinTri), and the frequently used solid MALDI matrixes 2,5-dihydroxybenzoic acid (DHB) and alpha-cyano-4-hydroxycinnamic acid (CHCA). The vacuum-stable, liquid consistency of ionic liquid matrix sample preparations considerably enhanced MALDI-MS analysis in terms of shot-to-shot reproducibility. Consequently, relative standard deviations serving as a measure for reproducibility of intensity-values acquired from 90 different spots on one MALDI-MS preparation were approximately one-half as high when solid DHB was replaced by the ionic liquid DHBB and eight times lower after exchange of solid CHCA by ionic liquid CHCAB. Interestingly, the ionic liquid MALDI matrix DHBB conserved the broad applicability of its solid analogue DHB, reduced MALDI induced fragmentation of monosialylated glycans and gangliosides, and was the superior ionic liquid matrix for MALDI-MS analysis of oligosaccharides and polymers, such as poly(ethylene glycol). It also worked well with glycoconjugates, peptides, and proteins; however, the tendency of DHBB to form multiple alkali adduct ions with peptides and proteins made CHCAB the ionic liquid matrix of choice for peptides. SinTri was the best ionic liquid matrix for proteins of high molecular weight, such as IgG. Furthermore, it was demonstrated for the first time that solvent properties and MALDI matrix properties of ionic liquids, such as DHBB, can be combined to enable fast, direct screening of an enzymatic reaction. This was proven by the desialylation of sialylactose with sialidase from Clostridium perfringens in the presence of diluted aqueous DHBB and subsequent direct MALDI-MS analysis of the reaction mixture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ionic liquids in analytical chemistry
Sun, P., & Armstrong, D. W. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.12.007 · Cited by 727
Application of ionic liquids in analytical chemistry
Liu, J.-F., Jiang, G.-B., Liu, J.-F., & Jönsson, J. Å. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2004.09.005 · Cited by 600
An analytical view of ionic liquids
Baker, G. A., Baker, S. N., Pandey, S., & Bright, F. V. (2005) · The Analyst · doi:10.1039/b500865b · Cited by 434
High-sensitivity Analytical Approaches for the Structural Characterization of Glycoproteins
Alley, W. R., Mann, B. F., & Novotny, M. V. (2013) · Chemical Reviews · doi:10.1021/cr3003714 · Cited by 310
Metadata
- Authors
- Mank, M., Stahl, B., & Boehm, G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-04-14
- Volume
- 76
- Issue
- 10
- Pages
- 2938-2950
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2010338295
- Cited by
- 210
- References
- 0
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 2,5-Dihydroxybenzoic Acid Butylamine and Other Ionic Liquid Matrixes for Enhanced MALDI-MS Analysis of Biomolecules. https://app.cochat.ai/papers/10.1021/ac030354j
- The paper
- Mank, M., Stahl, B., & Boehm, G. (2004). 2,5-Dihydroxybenzoic Acid Butylamine and Other Ionic Liquid Matrixes for Enhanced MALDI-MS Analysis of Biomolecules. Analytical Chemistry. https://doi.org/10.1021/ac030354j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.