Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 375

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Dielectrophoresis in Microchips Containing Arrays of Insulating Posts: Theoretical and Experimental Results

Cummings, Eric B., Singh, Anup K.·2003·Analytical Chemistry

Abstract

Dielectrophoresis (DEP), a nonlinear electrokinetic transport mechanism, can be used to concentrate and sort cells, viruses, and particles. To date, microfabricated DEP-based devices have typically used embedded metal electrodes to apply spatially nonuniform, time-varying (AC) electric fields. We have developed an alternative method in which arrays of insulating posts in a channel of a microchip produce the spatially nonuniform fields needed for DEP. Electrodes may be located remotely, allowing operation of the device down to zero frequency (DC) without excessive problems of electrolysis. Applying a sufficiently large electric field across an insulating-post array produces two flow regimes through a competition between electrokinetic flow (combined electrophoresis and electroosmosis) and dielectrophoresis. "Streaming DEP" is observed when DEP dominates diffusion but is overcome by electrokinetic flow. Particles concentrated by DEP forces in areas of electric field extrema travel electrokinetically down the array in flowing streams. In an array of posts, dielectrophoretic forcing within repeated rows adds coherently to produce flowing streams of highly concentrated and rarefied particles. We demonstrate that this reinforcement is a strong function of alignment of the array with respect to the applied electric field and that the particle concentrations can be "enhanced" or "depleted" along columns of posts, enabling a novel class of continuous-flow, selective particle filter/concentrator devices. To our knowledge, this is the first observation of streaming dielectrophoresis. The second regime is "trapping DEP," in which DEP forces dominate over both diffusion and electrokinetic flow, reversibly immobilizing particles on the insulating posts, enabling inexpensive and embedded batch filter/concentrator devices. Devices can be biased electrically to manipulate particles selectively by varying the field strength to vary the relative magnitudes of electrokinetic flow and DEP. Post shapes are contoured easily to control electric field gradients and, hence, DEP behavior. Simple simulations based on similitude of fluid flow and electric field that solve the Laplace equation to obtain fluid velocity have also been developed to predict the dielectrophoretic behavior in an array of posts. These simulations are in excellent agreement with the experimental observations and provide insight into electrokinetic behavior to enable design of dielectrophoretic concentrators and sorters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0340612

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 375

Metadata

Authors
Cummings, E. B., & Singh, A. K.
Venue
Analytical Chemistry
Published
2003-08-09
Volume
75
Issue
18
Pages
4724-4731
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2072887637
Cited by
375
References
9
FWCI
8.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dielectrophoresis in Microchips Containing Arrays of Insulating Posts: Theoretical and Experimental Results. https://app.cochat.ai/papers/10.1021/ac0340612
The paper
Cummings, E. B., & Singh, A. K. (2003). Dielectrophoresis in Microchips Containing Arrays of Insulating Posts: Theoretical and Experimental Results. Analytical Chemistry. https://doi.org/10.1021/ac0340612

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.