Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record.

A Dry Process for Production of Microfluidic Devices Based on the Lamination of Laser-Printed Polyester Films

Lucio do Lago, Claudimir, Torres da Silva, Heron Dominguez, Neves, Carlos Antonio, Alves Brito-Neto, José Geraldo, Fracassi da Silva, José Alberto·2003·Analytical Chemistry

Abstract

A new microfabrication process based on a xerographic process is described. A laser printer is used to selectively deposit toner on a polyester film, which is subsequently laminated against another polyester film. The toner layer binds the two polyester films and allows the blank regions to become channels for microfluidics. These software-outlined channels are approximately 6 microm deep. Approximately twice this depth is obtained by laminating two printed films. The resulting devices were not significantly damaged after 24 h of exposure to aqueous solutions of H3PO4, NaOH, methanol, acetonitrile, or sodium dodecyl sulfate. Electric tests with an impedance analyzer and microchannels filled with KCl solution demonstrated that (1) wide channels suffer from deformation of the top and bottom walls due to the lamination of the polyester films and (2) the toner walls are somewhat porous. Although these drawbacks limit the maximum width of a channel and the minimum distance between two channels, the process is an attractive option to other expensive, laborious, and time-consuming methods for microchannels fabrication. The process has been used to implement devices for electrospray tip and capillary electrophoresis with contactless conductivity detection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac034437b

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Lucio do Lago, C., Torres da Silva, H. D., Neves, C. A., Alves Brito-Neto, J. G., & Fracassi da Silva, J. A.
Venue
Analytical Chemistry
Published
2003-06-20
Volume
75
Issue
15
Pages
3853-3858
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2088892743
Cited by
172
References
0
FWCI
6.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.