The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Raman Detection of Proteomic Analytes
Abstract
The compatibility of nonenhanced Raman spectroscopy with chromatographic and mass spectroscopic proteomic sensing is demonstrated for the first time. High-quality normal Raman spectra are derived from protein solutions with concentrations down to 1 microM and 1 fmol of protein nondestructively probed within the excitation laser beam. These results are obtained using a drop coating deposition Raman (DCDR) method in which the solution of interest is microdeposited (or microprinted) on a compatible substrate, followed by solvent evaporation and backscattering detection. Representative applications include the DCDR detection of insulin derived from an HPLC fraction, nondestructive DCDR followed by MALDI-TOF of lysozyme, the DCDR detection of protein spots deposited using an ink-jet microprinter, and the identification of spectral differences between glycan isomers of equal mass (such as those derived from posttranslationally modified proteins).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluidity of Bound Hydration Layers
Raviv, U., & Klein, J. (2002) · Science · doi:10.1126/science.1074481 · Cited by 721
Cited by
Marangoni Effect Reverses Coffee-Ring Depositions
Hu, H., & Larson, R. G. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp0609232 · Cited by 1,645
Metadata
- Authors
- Zhang, D., Xie, Y., Mrozek, M. F., Ortiz, C., Davisson, V. J., & Ben-Amotz, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-09-20
- Volume
- 75
- Issue
- 21
- Pages
- 5703-5709
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1964759356
- Cited by
- 188
- References
- 1
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.