The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dielectrophoretic Concentration and Separation of Live and Dead Bacteria in an Array of Insulators
Abstract
Insulator-based (electrodeless) dielectrophoresis (iDEP) is an innovative approach in which the nonuniform electric field needed to drive DEP is produced by insulators, avoiding problems associated with the use of electrodes. Live and dead Escherichia coli were concentrated and selectively released by applying stepped DC voltages across a microchannel containing an array of insulating posts etched in glass. The only electrodes present were two platinum wires placed in the inlet and outlet reservoirs, producing mean electric fields of up to 200 V/mm across the insulators. The cells were labeled with Syto 9 and propidium iodide and imaged through a fluorescent microscope. Cell trapping and release were controlled by modifying the relative responses of electrokinesis and DEP by adjusting the magnitude of the applied voltage. Dead cells were observed to have significantly lower dielectrophoretic mobility than live cells, whereas the electrokinetic mobilities of live and dead cells were indistinguishable. The locations of the bands of differentially trapped cells were consistent with predictions. In addition, cells were selectively trapped and concentrated against backgrounds of 1- and 0.2-microm carboxylate-modified polystyrene particles. This first application of iDEP for simultaneous live/dead bacteria separation and concentration illustrates its potential as a front-end method for bacterial analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786
Cited by
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Dielectrophoresis for manipulation of micro/nano particles in microfluidic systems
Zhang, C., Khoshmanesh, K., Mitchell, A., & Kalantar-zadeh, K. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2922-6 · Cited by 305
Selective isolation of live/dead cells using contactless dielectrophoresis (cDEP)
Shafiee, H., Sano, M. B., Henslee, E. A., Caldwell, J. L., & Davalos, R. V. (2010) · Lab on a Chip · doi:10.1039/b920590j · Cited by 288
DC-Dielectrophoretic separation of biological cells by size
Kang, Y., Li, D., Kalams, S. A., & Eid, J. E. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9130-y · Cited by 276
Metadata
- Authors
- Lapizco-Encinas, B. H., Simmons, B. A., Cummings, E. B., & Fintschenko, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-02-18
- Volume
- 76
- Issue
- 6
- Pages
- 1571-1579
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1983847498
- Cited by
- 483
- References
- 1
- FWCI
- 16.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.