The DOI matches its Crossref record.
Suppression of α-Cyano-4-hydroxycinnamic Acid Matrix Clusters and Reduction of Chemical Noise in MALDI-TOF Mass Spectrometry
Abstract
Progress in high-throughput MALDI-TOFMS analysis, especially in proteome applications, requires development of practical and efficient procedures for the preparation of proteins and peptides in a form suitable for high acquisition rates. These methods should improve successful identification of peptides, which depends on the signal intensity and the absence of interfering signals. Contamination of MALDI samples with alkali salts results in reduced MALDI peptide sensitivity and causes matrix cluster formation (widely reported for CHCA matrix) observed as signals dominating in the range below m/z 1200 in MALDI spectra. One way to remove these background signals, especially for concentrations of peptides lower than 10 fmol/microL, is to wash matrix/sample spots after peptide cocrystallization on the MALDI plate with deionized water prior to analysis. This method takes advantage of the low water solubility of the CHCA compared to its alkali salts. We report here that the application of some ammonium salt solutions, such as citrates and phosphates, instead of deionized water greatly improves the efficiency of this washing approach. Another way to reduce matrix cluster formation is to add ammonium salts as a part of the MALDI matrix. The best results were obtained with monoammonium phosphate, which successfully suppressed matrix clusters and improved sensitivity. Combining both of these approaches-the addition of ammonium salts in the CHCA matrix followed by one postcrystallization washing step with ammonium buffer-provided a substantial ( approximately 3-5-fold) improvement in the sensitivity of MALDI-MS detection compared to unwashed sample spots. This sample preparation method resulted in improved spectral quality and was essential for successful database searching for subnanomolar concentrations of protein digests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Interferences and contaminants encountered in modern mass spectrometry
Keller, B. O., Sui, J., Young, A. B., & Whittal, R. M. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.043 · Cited by 623
Applications of MALDI Mass Spectrometry in Clinical Chemistry
Duncan, M. W., Nedelkov, D., Walsh, R., & Hattan, S. J. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.239491 · Cited by 96
Metadata
- Authors
- Smirnov, I. P., Zhu, X., Taylor, T., Huang, Y., Ross, P., Papayanopoulos, I. A., Martin, S. A., & Pappin, D. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-04-13
- Volume
- 76
- Issue
- 10
- Pages
- 2958-2965
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2043304722
- Cited by
- 174
- References
- 0
- FWCI
- 7.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.