The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Single-Drop Microextraction Combined with Low-Temperature Electrothermal Vaporization ICPMS for the Determination of Trace Be, Co, Pd, and Cd in Biological Samples
Abstract
A new method of single-drop microextraction combined with low-temperature electrothermal vaporization (LTETV)-ICPMS was proposed for the determination of trace Be, Co, Pd, and Cd with benzoylacetone (BZA) as both extractant and chemical modifier. Several factors that influence the microextraction efficiency, such as sample flow rate, microdrop volume, and extraction time, were investigated and the optimized microextraction conditions were established. Be, Co, Pd, and Cd in the postextraction organic phase were directly determined by LTETV-ICPMS with the use of BZA as chemical modifier. The chemical modification of BZA in LTETV-ICPMS was studied, and the factors affecting the formation of chelates and vaporization/transportation of chelates were investigated. Under the optimized conditions, the detection limits of the method were 0.12, 0.99, 1.5, and 0.27 pg/mL for Be, Co, Pd, and Cd, and the relative standard deviations for 0.1 ng/mL Be, Co, Pd, and Cd were 16, 14, 14, and 11%, respectively. After 10 min of extraction, the enrichment factors were 160 (Be), 125 (Co), 40 (Pd), and 180 (Cd). The proposed method was applied to the determination of trace Be, Co, Pd, and Cd in biological reference materials, and the determined values were in good agreement with the certified values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Developments in single-drop microextraction
Psillakis, E., & Kalogerakis, N. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00126-1 · Cited by 373
Cited by
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2009) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.10.042 · Cited by 414
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Xiong, J., & Hu, B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.03.072 · Cited by 228
Self-citationTrends in liquid-phase microextraction, and its application to environmental and biological samples
Han, D., & Row, K. H. (2012) · Microchimica Acta · doi:10.1007/s00604-011-0678-0 · Cited by 175
Metadata
- Authors
- Xia, L., Hu, B., Jiang, Z., Wu, Y., & Liang, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-04-07
- Volume
- 76
- Issue
- 10
- Pages
- 2910-2915
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2065023378
- Cited by
- 162
- References
- 2
- FWCI
- 11.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-Drop Microextraction Combined with Low-Temperature Electrothermal Vaporization ICPMS for the Determination of Trace Be, Co, Pd, and Cd in Biological Samples. https://app.cochat.ai/papers/10.1021/ac035437e
- The paper
- Xia, L., Hu, B., Jiang, Z., Wu, Y., & Liang, Y. (2004). Single-Drop Microextraction Combined with Low-Temperature Electrothermal Vaporization ICPMS for the Determination of Trace Be, Co, Pd, and Cd in Biological Samples. Analytical Chemistry. https://doi.org/10.1021/ac035437e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.