Protein Characterization by On-Line Capillary Isoelectric Focusing, Reversed-Phase Liquid Chromatography, and Mass Spectrometry
The DOI matches its Crossref record.
Abstract
Two-dimensional polyacrylmide gel electrophoresis (2D-PAGE), perhaps the most widely used method in proteomics research, is often limited by sensitivity and throughput. Capillary isoelectric focusing (CIEF) coupled with electrospray ionization (ESI) mass spectrometry (MS) provides a liquid-based alternative to 2D-PAGE that can overcome these problems but is limited by ampholyte interference and signal quenching in ESI-MS. Inserting a reversed-phase liquid chromatography (RPLC) step between CIEF and MS can remove this interference. In this work, a CIEF-RPLC-MS system is described for separation and characterization of proteins in complex mixtures. CIEF is performed with a microdialysis membrane-based cathodic cell that also permits protein fractions to be collected, washed to remove ampholyte, and analyzed by RPLC-MS. CIEF performance with this cell is equivalent to that achieved with a conventional cathodic cell, and no loss of protein is observed during faction collection. The cell can be easily and safely retrofitted into commercial instrumentation and is applicable for peptide analysis as well. Protein detection at the low-femtomole level is demonstrated with little or no interference from ampholyte, and CIEF-RPLC-MS data are used to construct a plot of pI vs MW for a protein mixture. The current instrumental configuration allows seven fractions in the pI range 3-10 to be analyzed by RPLC-MS in 2 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“cIEF has also been coupled to RPLC-MS, which allowed for a second dimension of separation and the removal of ampholytes which can cause significant ionization suppression [68].”
MethodTop-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Capillary electrophoresis–mass spectrometry for the analysis of intact proteins
Haselberg, R., de Jong, G. J., & Somsen, G. W. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.048 · Cited by 185
Combining capillary electrophoresis with mass spectrometry for applications in proteomics
Simpson, D. C., & Smith, R. D. (2005) · ELECTROPHORESIS · doi:10.1002/elps.200410132 · Cited by 178
Stutz, H. (2005) · ELECTROPHORESIS · doi:10.1002/elps.200410130 · Cited by 168
Metadata
- Authors
- Zhou, F., & Johnston, M. V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-04-14
- Volume
- 76
- Issue
- 10
- Pages
- 2734-2740
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2024632045
- Cited by
- 59
- References
- 0
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Protein Characterization by On-Line Capillary Isoelectric Focusing, Reversed-Phase Liquid Chromatography, and Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac035446n
- The paper
- Zhou, F., & Johnston, M. V. (2004). Protein Characterization by On-Line Capillary Isoelectric Focusing, Reversed-Phase Liquid Chromatography, and Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac035446n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.