Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 267

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Microelectrode Biosensor for Real-Time Measurement of ATP in Biological Tissue

Llaudet, Enrique, Hatz, Sonja, Droniou, Magali, Dale, Nicholas·2005·Analytical Chemistry

Abstract

The purines ATP, ADP, and adenosine are important extracellular signaling agents. Analysis of purinergic signaling has been slowed by lack of direct methods for measurement of purine release in real-time during physiological activity. We have previously reported microelectrode biosensors for adenosine, but similar sensors for ATP have remained elusive. We now describe an ATP biosensor formed by coating a Pt microelectrode with an ultrathin biolayer containing glycerol kinase and glycerol-3-phosphate oxidase. It responds rapidly (10-90% rise time <10 s) and exhibits a linear response to ATP over the physiologically relevant concentrations of 200 nM-50 microM and is very sensitive approximately 250 mA.M(-1).cm(-2). By including phosphocreatine kinase in the biolayer, we can optionally amplify the ATP signal and also make the sensor sensitive to external ADP. We have used our sensors to make the first demonstration that ATP is released from spinal networks in vivo during locomotor activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac048106q

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 267

Metadata

Authors
Llaudet, E., Hatz, S., Droniou, M., & Dale, N.
Venue
Analytical Chemistry
Published
2005-04-06
Volume
77
Issue
10
Pages
3267-3273
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2075095490
Cited by
267
References
25
FWCI
16.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.