The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Self-Referencing Ceramic-Based Multisite Microelectrodes for the Detection and Elimination of Interferences from the Measurement of l-Glutamate and Other Analytes
Abstract
A self-referencing technique utilizing two microelectrodes on a ceramic-based multisite array is employed for confirmation and elimination of interferences detected by enzyme-based microelectrodes. The measurement of L-glutamate using glutamate oxidase was the test system; however, other oxidase enzymes such as glucose oxidase can be employed. One recording site was coated with Nafion with L-glutamate oxidase and bovine serum albumin (BSA) cross-linked with glutaraldehyde while the other had Nafion with BSA cross-linked with glutaraldehyde. Differences in the chemistry of the two recording sites allowed for identification and elimination of interfering signals to be removed from the analyte response. The electrode showed low detection limits (LOD = 0.98 +/- 0.09 microM, signal-to-noise ratio of 3), fast response times (T90 approximately 1 s), and excellent linearity (R2 = 0.999 +/- 0.000) over the concentration range of 0-200 microM for calibrations of L-glutamate in vitro. The selectivity and dimensions of the multisite electrode allow in vivo glutamate measurements. This electrode has been applied to in vivo measurements of the clearance of locally applied glutamate and release of glutamate in the prefrontal cortex of anesthetized rats. In addition, a aimilar approach has been applied to the development of a microelectrode for measures of glucose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The rat brain in stereotaxic coordinates
Palkovits, M. (1983) · Neuropeptides · doi:10.1016/0143-4179(83)90049-5 · Cited by 28,831
Nafion-coated electrodes with high selectivity for CNS electrochemistry
Gerhardt, G. A., Oke, A. F., Nagy, G., Moghaddam, B., & Adams, R. N. (1984) · Brain Research · doi:10.1016/0006-8993(84)90963-6 · Cited by 633
Self-citationDesign and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Ceramic-Based Multisite Microelectrodes for Electrochemical Recordings
Burmeister, J. J., Moxon, K., & Gerhardt, G. A. (2000) · Analytical Chemistry · doi:10.1021/ac9907991 · Cited by 196
Self-citationRegional effects of aging on dopaminergic function in the Fischer-344 rat
Friedemann, M. N., & Gerhardt, G. A. (1992) · Neurobiology of Aging · doi:10.1016/0197-4580(92)90046-z · Cited by 173
Self-citationCordek, J., Wang, X., & Tan, W. (1999) · Analytical Chemistry · doi:10.1021/ac980850l · Cited by 120
Voltammetric Methods in Brain Systems
Boulton, A. A., Baker, G. B., & Adams, R. N. (1995) · Humana Press eBooks · doi:10.1385/0896033120 · Cited by 108
Netchiporouk, L. I., Shram, N. F., Jaffrezic-Renault, N. J., Martelet, C., & Cespuglio, R. (1996) · Analytical Chemistry · doi:10.1021/ac960190p · Cited by 94
Fabrication and Characterization of Sputtered-Carbon Microelectrode Arrays
Sreenivas, G., Ang, S. S., Fritsch, I., Brown, W. D., Gerhardt, G. A., & Woodward, D. J. (1996) · Analytical Chemistry · doi:10.1021/ac9508816 · Cited by 89
Self-citationShram, N. F., Netchiporouk, L. I., Martelet, C., Jaffrezic-Renault, N. J., Bonnet, C., & Cespuglio, R. (1998) · Analytical Chemistry · doi:10.1021/ac971299f · Cited by 70
Cited by
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Prefrontal Acetylcholine Release Controls Cue Detection on Multiple Timescales
Parikh, V., Kozak, R., Martinez, V., & Sarter, M. (2007) · Neuron · doi:10.1016/j.neuron.2007.08.025 · Cited by 623
Enzymatic glucose biosensor based on ZnO nanorod array grown by hydrothermal decomposition
Wei, A., Sun, X. W., Wang, J. X., Lei, Y., Cai, X. P., Li, C. M., Dong, Z. L., & Huang, W. (2006) · Applied Physics Letters · doi:10.1063/1.2356307 · Cited by 442
Using a Common Average Reference to Improve Cortical Neuron Recordings From Microelectrode Arrays
Ludwig, K. A., Miriani, R. M., Langhals, N. B., Joseph, M. D., Anderson, D. J., & Kipke, D. R. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90989.2008 · Cited by 420
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Metadata
- Authors
- Burmeister, J. J., & Gerhardt, G. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-01-26
- Volume
- 73
- Issue
- 5
- Pages
- 1037-1042
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1985615006
- Cited by
- 289
- References
- 13
- FWCI
- 12.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-Referencing Ceramic-Based Multisite Microelectrodes for the Detection and Elimination of Interferences from the Measurement of l-Glutamate and Other Analytes. https://app.cochat.ai/papers/10.1021/ac0010429
- The paper
- Burmeister, J. J., & Gerhardt, G. A. (2001). Self-Referencing Ceramic-Based Multisite Microelectrodes for the Detection and Elimination of Interferences from the Measurement of l-Glutamate and Other Analytes. Analytical Chemistry. https://doi.org/10.1021/ac0010429
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.