The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Amperometric Biosensors Based on Redox Polymer−Carbon Nanotube−Enzyme Composites
Abstract
Based on their size and unique electrical properties, carbon nanotubes offer the exciting possibility of developing ultrasensitive, electrochemical biosensors. In this study, we describe the construction of amperometric biosensors based on the incorporation of single-walled carbon nanotubes modified with enzyme into redox polymer hydrogels. The composite films were constructed by first incubating an enzyme in a single-walled carbon nanotube (SWNTs) solution and then cross-linking within a poly[(vinylpyridine)Os(bipyridyl)(2)Cl(2+/3+)] polymer film. Incorporation of SWNTs, modified with glucose oxidase, into the redox polymer films resulted in a 2-10-fold increase in the oxidation and reduction peak currents during cyclic voltammetry, while the glucose electrooxidation current was increased 3-fold to approximately 1 mA/cm(2) for glucose sensors. Similar effects were also observed when SWNTs were modified with horseradish peroxidase prior to incorporation into redox hydrogels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Helical microtubules of graphitic carbon
Iijima, S. (1991) · Nature · doi:10.1038/354056a0 · Cited by 43,098
Single-shell carbon nanotubes of 1-nm diameter
Iijima, S., & Ichihashi, T. (1993) · Nature · doi:10.1038/363603a0 · Cited by 9,012
Cobalt-catalysed growth of carbon nanotubes with single-atomic-layer walls
Bethune, D. S., Kiang, C. H., de Vries, M. S., Gorman, G., Savoy, R., Vazquez, J., & Beyers, R. (1993) · Nature · doi:10.1038/363605a0 · Cited by 4,038
Electrical conductivity of individual carbon nanotubes
Ebbesen, T. W., Lezec, H. J., Hiura, H., Bennett, J. W., Ghaemi, H. F., & Thio, T. (1996) · Nature · doi:10.1038/382054a0 · Cited by 2,642
Electrostatic Deflections and Electromechanical Resonances of Carbon Nanotubes
Poncharal, P., Wang, Z. L., Ugarte, D., & de Heer, W. A. (1999) · Science · doi:10.1126/science.283.5407.1513 · Cited by 1,934
Protein Electrochemistry Using Aligned Carbon Nanotube Arrays
Gooding, J. J., Wibowo, R., Liu, Yang, W., Losic, D., Orbons, S., Mearns, F. J., Shapter, J. G., & Hibbert, D. B. (2003) · Journal of the American Chemical Society · doi:10.1021/ja035722f · Cited by 881
Electrical wiring of redox enzymes
Heller, A. (1990) · Accounts of Chemical Research · doi:10.1021/ar00173a002 · Cited by 788
Direct electron transfer of glucose oxidase on carbon nanotubes
Guiseppi-Elie, A., Lei, C., & Baughman, R. H. (2002) · Nanotechnology · doi:10.1088/0957-4484/13/5/303 · Cited by 629
Long‐Range Electrical Contacting of Redox Enzymes by SWCNT Connectors
Patolsky, F., Weizmann, Y., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353275 · Cited by 609
Fast Electron Transfer Kinetics on Multiwalled Carbon Nanotube Microbundle Electrodes
Nugent, J. M., Santhanam, K. S. V., Rubio, Á., & Ajayan, P. M. (2001) · Nano Letters · doi:10.1021/nl005521z · Cited by 510
Cited by
Advanced Carbon Electrode Materials for Molecular Electrochemistry
McCreery, R. L. (2008) · Chemical Reviews · doi:10.1021/cr068076m · Cited by 2,729
Biosensors based on carbon nanotubes
Balasubramanian, K., & Burghard, M. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0314-8 · Cited by 727
Carbon nanotubes for electrochemical biosensing
RIVAS, G., RUBIANES, M., RODRIGUEZ, M., FERREYRA, N., LUQUE, G., PEDANO, M., MISCORIA, S., & PARRADO, C. (2007) · Talanta · doi:10.1016/j.talanta.2007.10.013 · Cited by 554
Bakker, E., & Qin, Y. (2006) · Analytical Chemistry · doi:10.1021/ac060637m · Cited by 392
Recent Advances in Nanotechnology Applied to Biosensors
Zhang, X., Guo, Q., & Cui, D. (2009) · Sensors · doi:10.3390/s90201033 · Cited by 382
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Non-Covalent Functionalization of Carbon Nanotubes for Electrochemical Biosensor Development
Zhou, Y., Fang, Y., & Ramasamy, R. (2019) · Sensors · doi:10.3390/s19020392 · Cited by 347
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Recent advances in carbon nanotube based electrochemical biosensors
Gupta, S., Murthy, C. N., & Prabha, C. R. (2018) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2017.12.038 · Cited by 279
Metadata
- Authors
- Joshi, P. P., Merchant, S. A., Wang, Y., & Schmidtke, D. W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-04-12
- Volume
- 77
- Issue
- 10
- Pages
- 3183-3188
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1967653668
- Cited by
- 262
- References
- 23
- FWCI
- 25.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.