The DOI matches its Crossref record.
Electrochemical Immunosensors for the Simultaneous Detection of Two Tumor Markers
Abstract
The microfabrication of electrochemical immunosensors for the simultaneous detection of two protein analytes is described. The sensors consisted of two iridium oxide electrodes (1-mm diameter) patterned on a glass substrate. Capture antibodies were immobilized on the porous iridium oxide electrodes by covalent attachment using (3-aminopropyl)triethoxysilane and glutaraldehyde. The spatial separation of the electrodes (2.5 mm) enabled simultaneous electrochemical immunoassays to be conducted without cross-talk between the electrodes. Proteins were measured using electrochemical ELISA, and detection was achieved by electrochemically oxidizing alkaline phosphatase-generated hydroquinone. Sensors for the simultaneous detection of goat IgG and mouse IgG, and for the tumor markers CEA and AFP, were developed. The sensors had detection limits of 1, 2, 1.2, and 1 ng/mL for goat IgG, mouse IgG, CEA, and AFP, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,454
Carbon Nanotube Amplification Strategies for Highly Sensitive Immunodetection of Cancer Biomarkers
Yu, X., Munge, B., Patel, V., Jensen, G., Bhirde, A., Gong, J. D., Kim, S. N., Gillespie, J., Gutkind, J. S., Papadimitrakopoulos, F., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja062117e · Cited by 686
Rocchitta, G., Spanu, A., Babudieri, S., Latte, G., Madeddu, G., Galleri, G., Nuvoli, S., Bagella, P., Demartis, M., Fiore, V., et al. (2016) · Sensors · doi:10.3390/s16060780 · Cited by 555
Measurement of biomarker proteins for point-of-care early detection and monitoring of cancer
Rusling, J. F., Kumar, C. V., Gutkind, J. S., & Patel, V. (2010) · The Analyst · doi:10.1039/c0an00204f · Cited by 552
Biosensors for cancer markers diagnosis
Tothill, I. E. (2009) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2009.01.015 · Cited by 552
Biomedical and clinical applications of immunoassays and immunosensors for tumor markers
Wu, J., Fu, Z., Yan, F., & Ju, H. (2007) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.05.007 · Cited by 461
Sandwich-type immunosensors and immunoassays exploiting nanostructure labels: A review
Pei, X., Zhang, B., Tang, J., Liu, B., Lai, W., & Tang, D. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.10.060 · Cited by 454
Vashist, S. K., Lam, E., Hrapovic, S., Male, K. B., & Luong, J. H. T. (2014) · Chemical Reviews · doi:10.1021/cr5000943 · Cited by 345
Status of biomolecular recognition using electrochemical techniques
Sadik, O. A., Aluoch, A. O., & Zhou, A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.003 · Cited by 315
The Role of Electrochemical Immunosensors in Clinical Analysis
Mollarasouli, F., Kurbanoglu, S., & Ozkan, S. A. (2019) · Biosensors · doi:10.3390/bios9030086 · Cited by 293
Ngoepe, M., Choonara, Y., Tyagi, C., Tomar, L., Du Toit, L., Kumar, P., Ndesendo, V., & Pillay, V. (2013) · Sensors · doi:10.3390/s130607680 · Cited by 92
Metadata
- Authors
- Wilson, M. S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-02-01
- Volume
- 77
- Issue
- 5
- Pages
- 1496-1502
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2038070260
- Cited by
- 245
- References
- 0
- FWCI
- 14.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.