Sol−Gel Modified Poly(dimethylsiloxane) Microfluidic Devices with High Electroosmotic Mobilities and Hydrophilic Channel Wall Characteristics
Abstract
Using a sol-gel method, we have fabricated poly(dimethylsiloxane) (PDMS) microchips with SiO2 particles homogeneously distributed within the PDMS polymer matrix. These particles are approximately 10 nm in diameter. To fabricate such devices, PDMS (Sylgard 184) was cast against SU-8 molds. After curing, the chips were carefully removed from the mold and sealed against flat, cured pieces of PDMS to form enclosed channel manifolds. These chips were then solvated in tetraethyl orthosilicate (TEOS), causing them to expand. Subsequently, the chips were placed in an aqueous solution containing 2.8% ethylamine and heated to form nanometer-sized SiO2 particles within the cross-linked PDMS polymer. The water contact angle for the PDMS-SiO2 chips was approximately 90.2 degrees compared to a water contact angle for Sylgard 184 of approximately 108.5 degrees . More importantly, the SiO2 modified PDMS chips showed no rhodamine B absorption after 4 h, indicating a substantially more hydrophilic and nonabsorptive surface than native PDMS. Initial electroosmotic mobilities (EOM) of (8.3+/-0.2)x10(-4) cm2/(V.s) (RSD=2.6% (RSD is relative standard deviation); n=10) were measured. This value was approximately twice that of native Sylgard 184 PDMS chips (4.21+/-0.09)x10(-4) cm2/(V.s) (RSD=2.2%; n=10) and 55% greater than glass chips (5.3+/-0.4)x10(-4) cm2/(V.s) (RSD=7.7%; n=5). After 60 days of dry storage, the EOM was (7.6+/-0.3)x10(-4) cm2/(V.s) (RSD=3.9%; n=3), a decrease of only 8% below that of the initially measured value. Separations performed on these devices generated 80,000-100,000 theoretical plates in 6-14 s for both tetramethylrhodamine succidimidyl ester and fluorescein-5-isothiocyanate derivatized amino acids. The separation distance was 3.5 cm. Plots of peak variance vs analyte migration times gave diffusion coefficients which indicate that the separation efficiencies are within 15% of the diffusion limit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bodas, D., & Khan-Malek, C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.037 · Cited by 600
Shakeri, A., Khan, S., & Didar, T. F. (2021) · Lab on a Chip · doi:10.1039/d1lc00288k · Cited by 312
Gomez-Sjoberg, R., Leyrat, A. A., Houseman, B. T., Shokat, K., & Quake, S. R. (2010) · Analytical Chemistry · doi:10.1021/ac101870s · Cited by 104
Metadata
- Authors
- Roman, G. T., Hlaus, T., Bass, K. J., Seelhammer, T. G., & Culbertson, C. T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-01-22
- Volume
- 77
- Issue
- 5
- Pages
- 1414-1422
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2001888948
- Cited by
- 223
- References
- 0
- FWCI
- 15.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sol−Gel Modified Poly(dimethylsiloxane) Microfluidic Devices with High Electroosmotic Mobilities and Hydrophilic Channel Wall Characteristics. https://app.cochat.ai/papers/10.1021/ac048811z
- The paper
- Roman, G. T., Hlaus, T., Bass, K. J., Seelhammer, T. G., & Culbertson, C. T. (2005). Sol−Gel Modified Poly(dimethylsiloxane) Microfluidic Devices with High Electroosmotic Mobilities and Hydrophilic Channel Wall Characteristics. Analytical Chemistry. https://doi.org/10.1021/ac048811z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.