Biocompatibility and reduced drug absorption of sol-gel-treated poly(dimethyl siloxane) for microfluidic cell culture applications
Open accessThe DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Abstract
Poly(dimethyl siloxane) (PDMS)-based microfluidic devices are now commonly used for a wide variety of biological experiments, including cell culture assays. However, the porous, hydrophobic polymer matrix of PDMS rapidly absorbs small hydrophobic molecules, including hormones and most small-molecule drugs. This makes it challenging to perform experiments that require such substances in PDMS microfluidic devices. This study presents evidence that a sol-gel treatment of PDMS that fills the polymer matrix with silica nanoparticles is effective at reducing the absorption of drugs into the material while preserving its biocompatibility, transparency, and oxygen permeability. We show that the absorption of two anticancer drugs, camptothecin and a kinase inhibitor, is reduced to such an extent that on-chip microfluidic cell culture experiments can recapitulate the results obtained off-chip.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Although PDMS holds many favorable properties for manufacturing microfluidic organ devices, it also has the potential drawback of adsorbing small and hydrophobic molecules.61, 62”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [62]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Self-citationMicrofluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Self-citationPDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Self-citationBiological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719
Pillai, O., & Panchagnula, R. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00227-1 · Cited by 710
Versatile, Fully Automated, Microfluidic Cell Culture System
Gómez-Sjöberg, R., Leyrat, A. A., Pirone, D. M., Chen, C. S., & Quake, S. R. (2007) · Analytical Chemistry · doi:10.1021/ac071311w · Cited by 625
Self-citationSurface modification of poly(dimethylsiloxane) microchannels
Makamba, H., Kim, J. H., Lim, K., Park, N., & Hahn, J. H. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305627 · Cited by 551
Mukhopadhyay, R. (2007) · Analytical Chemistry · doi:10.1021/ac071903e · Cited by 355
Cited by
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
“Hydrophobic molecules, less than approximately 500 Da, are absorbed into PDMS (Gomez-Sjoberg et al., 2010), which complicates the interpretation of some studies.”
BackgroundSelf-citationMicrofabrication of human organs-on-chips
Huh, D., Kim, H. J., Fraser, J. P., Shea, D. E., Khan, M., Bahinski, A., Hamilton, G. A., & Ingber, D. E. (2013) · Nature Protocols · doi:10.1038/nprot.2013.137 · Cited by 712
Microfluidic Organ-on-a-Chip Models of Human Intestine
Bein, A., Shin, W., Jalili-Firoozinezhad, S., Park, M. H., Sontheimer-Phelps, A., Tovaglieri, A., Chalkiadaki, A., Kim, H. J., & Ingber, D. E. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.12.010 · Cited by 625
Small molecule absorption by PDMS in the context of drug response bioassays
van Meer, B. J., de Vries, H., Firth, K. S. A., van Weerd, J., Tertoolen, L. G. J., Karperien, H. B. J., Jonkheijm, P., Denning, C., IJzerman, A. P., & Mummery, C. L. (2017) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2016.11.062 · Cited by 502
“These coatings have been reported to be biocompatible [16], but the presence of cells on compound absorption or coating degradation has not been investigated.”
BackgroundMehling, M., & Tay, S. (2014) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.10.005 · Cited by 390
Metadata
- Authors
- Gomez-Sjoberg, R., Leyrat, A. A., Houseman, B. T., Shokat, K., & Quake, S. R.
- Affiliations
- Engineering Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720, United States, Department of Bioengineering and Howard Hughes Medical Institute, Stanford University, Stanford, California 94305, United States, Department of Anesthesia and Perioperative Care, San Francisco General Hospital, San Francisco, California 94143, United States, and Department of Cellular and Molecular Pharmacology and Howard Hughes Medical Institute, University of California San Francisco, San Francisco,...
- San Francisco General Hospital (US)
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-10-11
- Volume
- 82
- Issue
- 21
- Pages
- 8954-8960
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- PMC
- PMC3032040
- OpenAlex
- W1964121777
- Cited by
- 104
- References
- 24
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 5 · 2023: 8 · 2022: 11 · 2021: 10 · 2020: 8 · 2019: 7 · 2018: 7 · 2017: 8 · 2016: 8 · 2015: 3 · 2014: 2 · 2013: 8 · 2012: 2
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Howard Hughes Medical Institute
- Mount Zion Health Fund
- National Institutes of Health (DP1OD000251)
- University of California, San Francisco
- National Cancer Institute
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- polydimethylsiloxane, sol-gel treatment, silica nanoparticles, drug absorption, microfluidic cell culture, biocompatibility, camptothecin, kinase inhibitors, anticancer agents, polymer surface modification
- MeSH terms
- Absorption, Antineoplastic Agents, Phytogenic, Biocompatible Materials, Camptothecin, Cell Line, Dimethylpolysiloxanes, Fibroblasts, Humans, Oxygen, Permeability, Cell Culture Techniques, Phase Transition, Microfluidic Analytical Techniques, Protein Kinase Inhibitors, Cell Proliferation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility and reduced drug absorption of sol-gel-treated poly(dimethyl siloxane) for microfluidic cell culture applications. https://app.cochat.ai/papers/10.1021/ac101870s
- The paper
- Gomez-Sjoberg, R., Leyrat, A. A., Houseman, B. T., Shokat, K., & Quake, S. R. (2010). Biocompatibility and reduced drug absorption of sol-gel-treated poly(dimethyl siloxane) for microfluidic cell culture applications. Analytical Chemistry. https://doi.org/10.1021/ac101870s
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.