Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 310

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Hydrophilic Affinity Isolation and MALDI Multiple-Stage Tandem Mass Spectrometry of Glycopeptides for Glycoproteomics

Wada, Yoshinao, Tajiri, Michiko, Yoshida, Shumi·2004·Analytical Chemistry

Abstract

In glycoproteomics, key structural issues, protein identification, locations of glycosylation sites, and evaluation of the glycosylation site microheterogeneity should be easily evaluated in a large number of glycoproteins, while mass spectrometry (MS) provides substantial information about individual purified glycoproteins. Considering that structural issues are elucidated by studying glycopeptides and that the tandem MS of a tryptic peptide composed of several amino acid residues is enough for protein identification, construction of an MS-based method handling tryptic glycopeptides would be of considerable benefit in research. To this end, a simple and efficient method, utilizing hydrophilic binding of carbohydrate matrixes such as cellulose and Sepharose to oligosaccharides, was successfully applied to the isolation of tryptic glycopeptides. Both peptide and oligosaccharide structures were elucidated by multiple-stage tandem MS (MS(n)) of the ions generated by matrix-assisted laser desorption/ionization (MALDI), as follows. The MALDI ion trap mass spectrum of a tryptic glycopeptide mixture from N-linked glycoproteins was composed of the [M + H]+ ions of component glycopeptides. Collision-induced dissociation (CID) of the glycopeptide [M + H]+ ion generated saccharide-spaced peaks, with an interval of, for example, 146, 162, and 203 Da, and their fragment ions corresponding to the peptide and peptide + N-acetylglucosamine (GlcNAc) species in the MS2 spectrum. The saccharide-spaced ladder served to outline oligosaccharide structures, which were then selected as precursors for subsequent MS(n) analyses. The peptide or peptide + GlcNAc ions in the MS2 spectrum or the corresponding ions abundant in the MS1 spectrum were subjected to CID for determination of peptide sequences, to identify proteins and their glycosylation sites. The strategy, isolation of glycopeptides followed by MS(n) analysis, efficiently characterized the structures of beta2-glycoprotein I with four N-glycosylation sites and was applied to an analysis of total serum glycoproteins.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac049062o

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 310

Metadata

Authors
Wada, Y., Tajiri, M., & Yoshida, S.
Venue
Analytical Chemistry
Published
2004-10-15
Volume
76
Issue
22
Pages
6560-6565
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2078301871
Cited by
310
References
18
FWCI
5.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.