Deformation-Induced Release of ATP from Erythrocytes in a Poly(dimethylsiloxane)-Based Microchip with Channels That Mimic Resistance Vessels
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The ability of nitric oxide to relax smooth muscle cells surrounding resistance vessels in vivo is well documented. Here, we describe a series of studies designed to quantify amounts of adenosine triphosphate (ATP), a known stimulus of NO production in endothelial cells, released from erythrocytes that are mechanically deformed as these cells traverse microbore channels in lithographically patterned microchips. Results indicate that micromolar amounts of ATP are released from erythrocytes flowing through channels having cross sectional dimensions of 60 x 38 micron (2.22 +/- 0.50 microM ATP). Microscopic images indicate that erythrocytes, when being pumped through the microchip channels, migrate toward the center of the channels, leaving a cell-free or skimming layer at the walls of the channel, a profile known to exist in circulatory vessels in vivo. A comparison of the amounts of ATP released from RBCs mechanically deformed in microbore tubing (2.54 +/- 0.15 microM) vs a microchip (2.59 +/- 0.32 microM) suggests that channels in microchips may serve as functional biomimics of the microvasculature. Control studies involving diamide, a membrane-stiffening agent, suggest that the RBC-derived ATP is not due to cell lysis but rather physical deformation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
The red blood cell as an oxygen sensor: what is the evidence?
Ellsworth, M. L. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00708.x · Cited by 186
Cited by
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Vickerman, V., Blundo, J., Chung, S., & Kamm, R. (2008) · Lab on a Chip · doi:10.1039/b802395f · Cited by 340
Dynamics of shear-induced ATP release from red blood cells
Wan, J., Ristenpart, W. D., & Stone, H. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805779105 · Cited by 279
Microfluidic Models of Vascular Functions
Wong, K. H. K., Chan, J. M., Kamm, R. D., & Tien, J. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150052 · Cited by 247
“Microfluidic channels have been applied to study this release in a variety of configurations (66).”
BackgroundStructure, kinetic properties and biological function of mechanosensitive Piezo channels
Fang, X.-Z., Zhou, T., Xu, J.-Q., Wang, Y.-X., Sun, M.-M., He, Y.-J., Pan, S.-W., Xiong, W., Peng, Z.-K., Gao, X.-H., et al. (2021) · Cell & Bioscience · doi:10.1186/s13578-020-00522-z · Cited by 226
Metadata
- Authors
- Price, A. K., Fischer, D. J., Martin, R. S., & Spence, D. M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-07-16
- Volume
- 76
- Issue
- 16
- Pages
- 4849-4855
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2072625307
- Cited by
- 69
- References
- 2
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.