CoChat

A Proteome Strategy for Fractionating Proteins and Peptides Using Continuous Free-Flow Electrophoresis Coupled Off-Line to Reversed-Phase High-Performance Liquid Chromatography

Moritz, Robert L., Ji, Hong, Schütz, Frédéric, Connolly, Lisa M., Kapp, Eugene A., Speed, Terence P., Simpson, Richard J. · 2004 · Analytical Chemistry
Cited by 111

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Extensive prefractionation is now considered to be a necessary prerequisite for the comprehensive analysis of complex proteomes where the dynamic range of protein abundances can vary from approximately 10(6) for cells to approximately 10(10) for tissues such as blood. Here, we describe a high-resolution 2D protein separation system that uses a continuous free-flow electrophoresis (FFE) device to fractionate complex protein mixtures by solution-phase isoelectric focusing (IEF) into 96 well-defined pools, each separated by approximately 0.02-0.10 pH unit depending on the gradient created, followed by rapid (approximately 6 min per analysis) reversed-phase high-performance liquid chromatography (RP-HPLC) of each FFE pool. Fractionated proteins are readily visualized in a virtual 2D format using software that plots protein loci, pI in the first dimension and relative hydrophobicity (i.e., RP-HPLC retention time) in the second dimension. By coupling a diode-array detector in line with a multiwavelength fluorescence detector, separated proteins can be monitored in the RP-HPLC eluent by both UV absorbance and intrinsic fluorescence simultaneously from a single experiment. Triplicate analyses of standard proteins using a pH 3-10 gradient conducted over a 3-day period revealed a high system reproducibility with a SD of 0.57 (0.05 pH unit) within the FFE pools and 0.003 (0.18 s) for protein retention times in the second-dimension RP-HPLC step. In addition, we demonstrate that the FFE-IEF/RP-HPLC separation strategy can also be applied to complex mixtures of low molecular weight compounds such as peptides. With the facile ability to measure the pH of the isoelectric focused pools, peptide pI values can be estimated and used to qualify peptide identifications made using either MS/MS sequencing approaches or pI discriminated peptide mass fingerprinting. The calculated peak capacity of this 2D liquid-based FFE-IEF/RP-HPLC system is 6720.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac049717l

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 111

Metadata

Authors
Moritz, R. L., Ji, H., Schütz, F., Connolly, L. M., Kapp, E. A., Speed, T. P., & Simpson, R. J.
Venue
Analytical Chemistry
Published
2004-07-09
Volume
76
Issue
16
Pages
4811-4824
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2022164275
Cited by
111
References
2
FWCI
6.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Proteome Strategy for Fractionating Proteins and Peptides Using Continuous Free-Flow Electrophoresis Coupled Off-Line to Reversed-Phase High-Performance Liquid Chromatography. https://app.cochat.ai/papers/10.1021/ac049717l
The paper
Moritz, R. L., Ji, H., Schütz, F., Connolly, L. M., Kapp, E. A., Speed, T. P., & Simpson, R. J. (2004). A Proteome Strategy for Fractionating Proteins and Peptides Using Continuous Free-Flow Electrophoresis Coupled Off-Line to Reversed-Phase High-Performance Liquid Chromatography. Analytical Chemistry. https://doi.org/10.1021/ac049717l

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.