Curve-Fitting Method for Direct Quantitation of Compounds in Complex Biological Mixtures Using 1H NMR: Application in Metabonomic Toxicology Studies
The DOI matches its Crossref record.
Abstract
A new software tool has been developed that provides automated measurement of signal intensities in NMR spectra of complex mixtures without using data reduction procedures. The algorithm finds best-fit transformations between signals in reference compound spectra and the corresponding signals in analyte spectra. Unlike other algorithms, it is insensitive to variation in chemical shift and can even be used for relative quantitation of compounds whose identities have not yet been established. Additionally, the parameters of the transformation provide information and error metrics that may assist in the streamlining of quality control. The approach presented is general in scope but has been tested by application to peak quantitation in NMR spectra of biofluids. Replicate NMR measurements of solutions of biologically important compounds at various concentrations were made. Further NMR data were collected on urine samples from human, rat, and mouse, which were "spiked" with reference compound solutions at known concentrations. Finally, existing data from an independent toxicology project involving several hundred samples were analyzed, and the consistency of the measurements for metabolites that give multiple NMR signals was assessed. The results of all these tests give confidence that the technique can be used in automated quantitation of compounds in large NMR data sets with minimal operator intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human metabolic phenotype diversity and its association with diet and blood pressure
Holmes, E., Loo, R. L., Stamler, J., Bictash, M., Yap, I. K. S., Chan, Q., Ebbels, T., De Iorio, M., Brown, I. J., Veselkov, K. A., et al. (2008) · Nature · doi:10.1038/nature06882 · Cited by 1,054
Self-citationTargeted Profiling: Quantitative Analysis of 1H NMR Metabolomics Data
Weljie, A. M., Newton, J., Mercier, P., Carlson, E., & Slupsky, C. M. (2006) · Analytical Chemistry · doi:10.1021/ac060209g · Cited by 900
Quantitative 1H NMR spectroscopy
Bharti, S. K., & Roy, R. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.02.007 · Cited by 799
Quantitative metabolomics using NMR
Wishart, D. S. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.001 · Cited by 582
Dona, A. C., Jiménez, B., Schäfer, H., Humpfer, E., Spraul, M., Lewis, M. R., Pearce, J. T. M., Holmes, E., Lindon, J. C., & Nicholson, J. K. (2014) · Analytical Chemistry · doi:10.1021/ac5025039 · Cited by 540
Self-citation
Metadata
- Authors
- Crockford, D. J., Keun, H. C., Smith, L. M., Holmes, E., & Nicholson, J. K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-06-15
- Volume
- 77
- Issue
- 14
- Pages
- 4556-4562
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1972591669
- Cited by
- 81
- References
- 0
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Curve-Fitting Method for Direct Quantitation of Compounds in Complex Biological Mixtures Using 1H NMR: Application in Metabonomic Toxicology Studies. https://app.cochat.ai/papers/10.1021/ac0503456
- The paper
- Crockford, D. J., Keun, H. C., Smith, L. M., Holmes, E., & Nicholson, J. K. (2005). Curve-Fitting Method for Direct Quantitation of Compounds in Complex Biological Mixtures Using 1H NMR: Application in Metabonomic Toxicology Studies. Analytical Chemistry. https://doi.org/10.1021/ac0503456
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.