Cited by 540Metabolomics and Mass Spectrometry StudiesAdvanced NMR Techniques and ApplicationsAdvanced MRI Techniques and Applications

Precision High-Throughput Proton NMR Spectroscopy of Human Urine, Serum, and Plasma for Large-Scale Metabolic Phenotyping

Dona, Anthony C., Jiménez, Beatriz, Schäfer, Hartmut, Humpfer, Eberhard, Spraul, Manfred, Lewis, Matthew R., Pearce, Jake T. M., Holmes, Elaine +2 more·2014·Analytical Chemistry

Abstract

Proton nuclear magnetic resonance (NMR)-based metabolic phenotyping of urine and blood plasma/serum samples provides important prognostic and diagnostic information and permits monitoring of disease progression in an objective manner. Much effort has been made in recent years to develop NMR instrumentation and technology to allow the acquisition of data in an effective, reproducible, and high-throughput approach that allows the study of general population samples from epidemiological collections for biomarkers of disease risk. The challenge remains to develop highly reproducible methods and standardized protocols that minimize technical or experimental bias, allowing realistic interlaboratory comparisons of subtle biomarker information. Here we present a detailed set of updated protocols that carefully consider major experimental conditions, including sample preparation, spectrometer parameters, NMR pulse sequences, throughput, reproducibility, quality control, and resolution. These results provide an experimental platform that facilitates NMR spectroscopy usage across different large cohorts of biofluid samples, enabling integration of global metabolic profiling that is a prerequisite for personalized healthcare.

Integrity signals

Registry

Crossref · 10.1021/ac5025039

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Dona, A. C., Jiménez, B., Schäfer, H., Humpfer, E., Spraul, M., Lewis, M. R., Pearce, J. T. M., Holmes, E., Lindon, J. C., & Nicholson, J. K.
Affiliations
  • Hammersmith Hospital (GB)
  • St Mary's Hospital (GB)
  • Bruker (Germany) (DE)
  • Imperial College London (GB)
Corresponding author
Nicholson, Jeremy K.
Venue
Analytical Chemistry
Published
2014-09-16
Volume
86
Issue
19
Pages
9887-9894
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2069637401
Cited by
540
References
47
Citations by year
2026: 46 · 2025: 42 · 2024: 43 · 2023: 64 · 2022: 49 · 2021: 52 · 2020: 51 · 2019: 43 · 2018: 47 · 2017: 37 · 2016: 44 · 2015: 20 · 2014: 1
FWCI
13.86
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
Waters Corporation
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
  • Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
Keywords
1H NMR, high-throughput NMR, metabolic phenotyping, human urine, serum, plasma, biomarkers, disease risk, experimental protocol standardization, reproducibility, interlaboratory comparison, biological fluids, quality control, personalized healthcare
MeSH terms
Humans, Magnetic Resonance Spectroscopy, Protons, Quality Control, Specimen Handling, Reproducibility of Results, Biomarkers, Metabolomics, Metabolome

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›