The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Peptide Nanotube-Modified Electrodes for Enzyme−Biosensor Applications
Abstract
The fabrication and notably improved performance of composite electrodes based on modified self-assembled diphenylalanine peptide nanotubes is described. Peptide nanotubes were attached to gold electrodes, and we studied the resulting electrochemical behavior using cyclic voltammetry and chronoamperometry. The peptide nanotube-based electrodes demonstrated a direct and unmediated response to hydrogen peroxide and NADH at a potential of +0.4 V (vs SCE). This biosensor enables a sensitive determination of glucose by monitoring the hydrogen peroxide produced by an enzymatic reaction between the glucose oxidase attached to the peptide nanotubes and glucose. In addition, the marked electrocatalytic activity toward NADH enabled a sensitive detection of ethanol using ethanol dehydrogenase and NAD+. The peptide nanotube-based amperometric biosensor provides a potential new tool for sensitive biosensors and biomolecular diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Cited by
Self-assembly and application of diphenylalanine-based nanostructures
Yan, X., Zhu, P., & Li, J. (2010) · Chemical Society Reviews · doi:10.1039/b915765b · Cited by 1,044
Self-assembling peptide and protein amyloids: from structure to tailored function in nanotechnology
Wei, G., Su, Z., Reynolds, N. P., Arosio, P., Hamley, I. W., Gazit, E., & Mezzenga, R. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00542j · Cited by 904
Self-citationSHANKARAN, D., GOBI, K., & MIURA, N. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.09.014 · Cited by 607
Self-assembling peptide semiconductors
Tao, K., Makam, P., Aizen, R., & Gazit, E. (2017) · Science · doi:10.1126/science.aam9756 · Cited by 490
Self-citationβ Galactosidases and their potential applications: a review
Husain, Q. (2010) · Critical Reviews in Biotechnology · doi:10.3109/07388550903330497 · Cited by 420
Metadata
- Authors
- Yemini, M., Reches, M., Gazit, E., & Rishpon, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-06-30
- Volume
- 77
- Issue
- 16
- Pages
- 5155-5159
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2007157792
- Cited by
- 256
- References
- 1
- FWCI
- 10.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Peptide Nanotube-Modified Electrodes for Enzyme−Biosensor Applications. https://app.cochat.ai/papers/10.1021/ac050414g
- The paper
- Yemini, M., Reches, M., Gazit, E., & Rishpon, J. (2005). Peptide Nanotube-Modified Electrodes for Enzyme−Biosensor Applications. Analytical Chemistry. https://doi.org/10.1021/ac050414g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.