The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Low-Level Detection of Viral Pathogens by a Surface-Enhanced Raman Scattering Based Immunoassay
Abstract
The need for rapid, highly sensitive, and versatile diagnostic tests for viral pathogens spans from human and veterinary medicine to bioterrorism prevention. As an approach to meet these demands, a diagnostic test employing monoclonal antibodies (mAbs) for the selective extraction of viral pathogens from a sample in a chip-scale, sandwich immunoassay format has been developed using surface-enhanced Raman scattering (SERS) as a readout method. The strengths of SERS-based detection include its inherent high sensitivity and facility for multiplexing. The capability of this approach is demonstrated by the capture of feline calicivirus (FCV) from cell culture media that is exposed to a gold substrate modified with a covalently immobilized layer of anti-FCV mAbs. The surface-bound FCVs are subsequently coupled with an extrinsic Raman label (ERL) for identification and quantification. The ERLs consist of 60-nm gold nanoparticles coated first with a layer of Raman reporter molecules and then a layer of mAbs. The Raman reporter molecule is strategically designed to chemisorb as a thiolate adlayer on the gold nanoparticle, to provide a strong and unique spectral signature, and to covalently link a layer of mAbs to the gold nanoparticle. The last feature provides a means to selectively tag substrate-bound FCV. This paper describes the development of the assay, which uses cell culture media as a sample matrix and has a linear dynamic range of 1 x 10(6)-2.5 x 10(8) viruses/mL and a limit of detection of 1 x 10(6) viruses/mL. These results reflect the findings from a detailed series of investigations on the effects of several experimental parameters (e.g., salt concentration, ERL binding buffer, and sample agitation), all of which were aimed at minimizing nonspecific binding and maximizing FCV binding efficiency. The performance of the assay is correlated with the number of captured FCV, determined by atomic force microscopy, as a means of method validation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface-enhanced Raman scattering and biophysics
Kneipp, K., Kneipp, H., Itzkan, I., Dasari, R. R., & Feld, M. S. (2002) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/14/18/202 · Cited by 998
Grubisha, D. S., Lipert, R. J., Park, H.-Y., Driskell, J., & Porter, M. D. (2003) · Analytical Chemistry · doi:10.1021/ac034356f · Cited by 779
Self-citationFluidity of Bound Hydration Layers
Raviv, U., & Klein, J. (2002) · Science · doi:10.1126/science.1074481 · Cited by 721
Geoghegan, W. D., & Ackerman, G. A. (1977) · Journal of Histochemistry & Cytochemistry · doi:10.1177/25.11.21217 · Cited by 604
Mulvaney, S. P., Musick, M. D., Keating, C. D., & Natan, M. J. (2003) · Langmuir · doi:10.1021/la026706j · Cited by 457
Glaser, R. W. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1399 · Cited by 361
Wagner, P., Hegner, M., Kernen, P., Zaugg, F., & Semenza, G. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79810-7 · Cited by 204
Contact-Inking Stamps for Microcontact Printing of Alkanethiols on Gold
Libioulle, L., Bietsch, A., Schmid, H., Michel, B., & Delamarche, E. (1999) · Langmuir · doi:10.1021/la980978y · Cited by 174
Faulds, K., Barbagallo, R. P., Keer, J. T., Smith, W. E., & Graham, D. (2004) · The Analyst · doi:10.1039/b406423b · Cited by 130
A feline kidney cell line-based plaque assay for feline calicivirus, a surrogate for Norwalk virus
Bidawid, S., Malik, N., Adegbunrin, O., Sattar, S. A., & Farber, J. (2002) · Journal of Virological Methods · doi:10.1016/s0166-0934(02)00214-8 · Cited by 117
Cited by
SERS as a bioassay platform: fundamentals, design, and applications
Porter, M. D., Lipert, R. J., Siperko, L. M., Wang, G., & Narayanan, R. (2008) · Chemical Society Reviews · doi:10.1039/b708461g · Cited by 580
Self-citationMultiplex in vitro detection using SERS
Laing, S., Gracie, K., & Faulds, K. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00644a · Cited by 361
Spectral Analysis of Multiplex Raman Probe Signatures
Lutz, B. R., Dentinger, C. E., Nguyen, L. N., Sun, L., Zhang, J., Allen, A. N., Chan, S., & Knudsen, B. S. (2008) · ACS Nano · doi:10.1021/nn800243g · Cited by 135
Schütz, M., & Schlücker, S. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4913 · Cited by 24
Metadata
- Authors
- Driskell, J. D., Kwarta, K. M., Lipert, R. J., Porter, M. D., Neill, J. D., & Ridpath, J. F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-08-27
- Volume
- 77
- Issue
- 19
- Pages
- 6147-6154
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2009321278
- Cited by
- 295
- References
- 12
- FWCI
- 9.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-Level Detection of Viral Pathogens by a Surface-Enhanced Raman Scattering Based Immunoassay. https://app.cochat.ai/papers/10.1021/ac0504159
- The paper
- Driskell, J. D., Kwarta, K. M., Lipert, R. J., Porter, M. D., Neill, J. D., & Ridpath, J. F. (2005). Low-Level Detection of Viral Pathogens by a Surface-Enhanced Raman Scattering Based Immunoassay. Analytical Chemistry. https://doi.org/10.1021/ac0504159
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.