Development and Evaluation of a Reference Measurement Procedure for the Determination of Estradiol-17β in Human Serum Using Isotope-Dilution Liquid Chromatography−Tandem Mass Spectrometry
The DOI matches its Crossref record.
Abstract
Estradiol is the most potent natural estrogen and is derived from the ovaries. Its concentration in blood is measured to determine ovarian function. A reference measurement procedure for estradiol in serum involving isotope-dilution coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. A deuterated estradiol (estradiol-d3) was used as an internal standard. The estradiol and its internal standard were extracted from serum matrix using solid-phase extractions and derivatized with dansyl chloride prior to reversed-phase LC/MS/MS. The accuracy of the measurement was evaluated by a comparison of results of this reference method on lyophilized human serum reference materials for estradiol [Certified Reference Materials (CRMs) 576, 577, and 578] with the certified values determined by gas chromatography/mass spectrometry (GC/MS) reference methods and by a recovery study for the added estradiol. The results of this method for estradiol agreed with the certified values within the uncertainty of the measurements for the three CRMs. The recovery of the added estradiol ranged from 100.7 to 101.8%. This method was applied to the determination of estradiol in frozen serum samples from three individual female donors. Excellent reproducibility was obtained with within-set coefficient of variations (CVs) ranging from 0.6 to 2.2% and between-set CVs ranging from 0.2 to 0.4%. Excellent linearity was also obtained, with correlation coefficients of all linear regression lines (measured intensity ratios vs mass ratios) ranging from 0.998 to 1.000. The detection limit at a signal-to-noise ratio of approximately 3 was 0.6 pg of estradiol (or 1 ng/L, as expressed as a concentration). This well-characterized LC/MS/MS method for serum estradiol, which demonstrates good accuracy and precision, low susceptibility to interferences, and comparability with GC/MS reference methods, qualifies as a reference measurement procedure that can be used to provide an accuracy base to which routine methods for estradiol can be compared and that will serve as a standard of higher order for measurement traceability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stable-Isotope Dilution LC–MS for Quantitative Biomarker Analysis
Ciccimaro, E., & Blair, I. A. (2010) · Bioanalysis · doi:10.4155/bio.09.185 · Cited by 226
Comparison of Methods to Measure Low Serum Estradiol Levels in Postmenopausal Women
Lee, J. S., Ettinger, B., Stanczyk, F. Z., Vittinghoff, E., Hanes, V., Cauley, J. A., Chandler, W., Settlage, J., Beattie, M. S., Folkerd, E., et al. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-2378 · Cited by 202
Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry
Santa, T. (2011) · Biomedical Chromatography · doi:10.1002/bmc.1548 · Cited by 163
The role of liquid chromatography–tandem mass spectrometry in the clinical laboratory
van den Ouweland, J. M. W., & Kema, I. P. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.11.044 · Cited by 161
Carvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90
Boggs, A. S. P., Bowden, J. A., Galligan, T. M., Guillette, L. J., & Kucklick, J. R. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9512-1 · Cited by 71
Zengul, A. G., Demark-Wahnefried, W., Barnes, S., Morrow, C. D., Bertrand, B., Berryhill, T. F., & Frugé, A. D. (2021) · Nutrition and Cancer · doi:10.1080/01635581.2020.1784444 · Cited by 60
“Estrogen analyses were determined by isotope dilution HPLC-electrospray ionization-multiple reaction ion mass spectrometry adapted from the method of Tai and Welch (18).”
MethodKeski‐Rahkonen, P., Huhtinen, K., Desai, R., Tim Harwood, D., Handelsman, D. J., Poutanen, M., & Auriola, S. (2013) · Journal of Mass Spectrometry · doi:10.1002/jms.3252 · Cited by 47
Metadata
- Authors
- Tai, S. S.-C., & Welch, M. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-08-26
- Volume
- 77
- Issue
- 19
- Pages
- 6359-6363
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2625764402
- Cited by
- 125
- References
- 0
- FWCI
- 10.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.