Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record.

Charge Transfer through DNA: A Selective Electrochemical DNA Biosensor

Wong, Elicia L. S., Gooding, J. Justin·2006·Analytical Chemistry

Abstract

The charge-transfer properties of DNA duplexes are exploited to produce a fast, simple, sensitive, and selective DNA biosensor by exposing the DNA recognition interface to a sample containing target DNA and the redox-active intercalator, anthraquinonemonosulfonic acid (AQMS). Electrochemistry from electron transfer through the DNA to AQMS intercalated into DNA duplexes can be differentiated from electrochemistry due to direct access of the AQMS to the electrode surface due to the difference in the environment of the AQMS giving a shift in the potential at which the molecule is reduced. The ability to distinguish between the two electrochemical signals enables DNA hybridization to be monitored in real time. This in situ detection scheme has good selectivity, being able to differentiate between a complementary target DNA sequence and one containing either C-A or G-A single-base mismatches. The concentration detection limit of the biosensor is 0.5 nM (1 pmol) with an assay time of 1 h. The fact that the end user is only required to simultaneously add the sample containing the target DNA and AQMS gives a DNA biosensor that is highly compatible with PCR on chip technologies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0509096

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Wong, E. L. S., & Gooding, J. J.
Venue
Analytical Chemistry
Published
2006-02-28
Volume
78
Issue
7
Pages
2138-2144
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2149061780
Cited by
172
References
0
FWCI
6.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.