Combined Top-Down and Bottom-Up Mass Spectrometric Approach to Characterization of Biomarkers for Renal Disease
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Here we describe a mass spectrometry (MS) approach for biomarker discovery and structural characterization, based on both top-down and bottom-up analyses. Capillary electrophoresis (CE) coupled to electrospray ionization (ESI) time-of-flight (TOF) MS serves to separate and mass-measure the thousands of polypeptides contained in human urine. Statistical analysis of the differences between healthy control samples and patients with focal-segmental glomerulosclerosis, membranous glomerulonephritis, minimal change disease, IgA nephropathy, and diabetic nephropathy validates multiple biomarkers for the control and each of the diseases. To identify those biomarkers, we employ preparative CE, enabling direct infusion ESI MS analysis, followed by sample manipulation and reanalysis where necessary. We show how tandem Fourier transform ion cyclotron resonance (FT-ICR) MS identifies these sometimes large (>8 kDa) biomarkers. Critically, we maintain connectivity between the CE TOF MS data and the ICR data used for biomarker identification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of proteomic patterns in serum to identify ovarian cancer
Petricoin, E. F., Ardekani, A. M., Hitt, B. A., Levine, P. J., Fusaro, V. A., Steinberg, S. M., Mills, G. B., Simone, C., Fishman, D. A., Kohn, E. C., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07746-2 · Cited by 3,236
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Cited by
Naturally Occurring Human Urinary Peptides for Use in Diagnosis of Chronic Kidney Disease
Good, D. M., Zürbig, P., Argilés, À., Bauer, H. W., Behrens, G., Coon, J. J., Dakna, M., Decramer, S., Delles, C., Dominiczak, A. F., et al. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.001917 · Cited by 524
Self-citationDecramer, S., de Peredo, A. G., Breuil, B., Mischak, H., Monsarrat, B., Bascands, J.-L., & Schanstra, J. P. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r800001-mcp200 · Cited by 450
Self-citationDiscovery and validation of new protein biomarkers for urothelial cancer: a prospective analysis
Theodorescu, D., Wittke, S., Ross, M. M., Walden, M., Conaway, M., Just, I., Mischak, H., & Frierson, H. F. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70584-8 · Cited by 410
Self-citationCurrent issues in measurement and reporting of urinary albumin excretion
Miller, W. G., Bruns, D. E., Hortin, G. L., Sandberg, S., Aakre, K. M., McQueen, M. J., Itoh, Y., Lieske, J. C., Seccombe, D. W., Jones, G., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.106567 · Cited by 381
Hertkorn, N., Ruecker, C., Meringer, M., Gugisch, R., Frommberger, M., Perdue, E. M., Witt, M., & Schmitt-Kopplin, P. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1577-4 · Cited by 294
Metadata
- Authors
- Chalmers, M. J., Mackay, C. L., Hendrickson, C. L., Wittke, S., Walden, M., Mischak, H., Fliser, D., Just, I., & Marshall, A. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-10-14
- Volume
- 77
- Issue
- 22
- Pages
- 7163-7171
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2030404152
- Cited by
- 89
- References
- 2
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.