Identification of Peptides Using Gold Nanoparticle-Assisted Single-Drop Microextraction Coupled with AP-MALDI Mass Spectrometry
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A novel technique, gold nanoparticle-assisted single-drop microextraction (SDME) combined with atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry (AP-MALDI-MS) for the identification of peptides has been described. The SDME of peptides from aqueous solution was achieved using gold nanoparticles prepared in toluene as the acceptor phase. A simple phenomenon of isoelectric point (pI) of the peptides has been utilized successfully to extract the peptides into a single drop of nanogold in toluene. After extraction, a single-drop nano gold solution was directly spotted onto the target plate with an equal volume of matrix, proportional, variant-cyanohydroxy cinnamic acid ( proportional, variant-CHCA) and analyzed in AP-MALDI-MS. The parameters, such as solvent selection, extraction time, agitation rate, and pH effect, were optimized for the SDME technique. Using this technique, in aqueous solution, the lowest concentration detected for Met- and Leu-enkephalin peptides was 0.2 and 0.17 microM, respectively. In addition, the application of this technique to obtain the signal for the selected peptides in a mass spectrum in the presence of matrix interferences such as 1% Triton X-100 and 6.5 M urea has been showed. The application was extended to identify the peptides spiked into urine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00836-0 · Cited by 468
Cited by
Li, D., Chen, Y., & Liu, Z. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00013k · Cited by 586
Recent applications of carbon-based nanomaterials in analytical chemistry: Critical review
Scida, K., Stege, P. W., Haby, G., Messina, G. A., & García, C. D. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.02.025 · Cited by 432
Developments in single-drop microextraction
Xu, L., Basheer, C., & Lee, H. K. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.073 · Cited by 382
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Application of functionalized magnetic nanoparticles in sample preparation
Xie, L., Jiang, R., Zhu, F., Liu, H., & Ouyang, G. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7302-6 · Cited by 266
Nanomaterials as sorbents for sample preparation in bioanalysis: A review
Ahmadi, M., Elmongy, H., Madrakian, T., & Abdel-Rehim, M. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.11.062 · Cited by 258
Liquid-phase microextraction techniques within the framework of green chemistry
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.016 · Cited by 221
The use of magnetic nanoparticles in sample preparation devices and tools
Keçili, R., Büyüktiryaki, S., Dolak, İ., & Hussain, C. M. (2020) · Handbook of Nanomaterials in Analytical Chemistry · doi:10.1016/b978-0-12-816699-4.00005-0 · Cited by 64
Single-Drop Microextraction in Bioanalysis
Choi, K., Kim, J., & Chung, D. S. (2011) · Bioanalysis · doi:10.4155/bio.11.3 · Cited by 42
Metadata
- Authors
- Sudhir, P.-R., Wu, H.-F., & Zhou, Z.-C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-10-05
- Volume
- 77
- Issue
- 22
- Pages
- 7380-7385
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1980664291
- Cited by
- 105
- References
- 2
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.