Kinetic Calibration for Automated Headspace Liquid-Phase Microextraction
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The kinetics of the absorption and desorption of analytes for headspace liquid-phase microextraction (HS-LPME) were studied. It was found that the desorption of analytes from the extraction phase into the sample matrix is isotropic to the absorption of the analytes from the sample matrix into the extraction phase under the same conditions. This therefore allows for the calibration of absorption using desorption. Calibration was accomplished by exposing the extraction phase, which contained a standard, to the sample matrix. The information from the desorption of the standard, such as time constant a, could be directly used to estimate the concentration of the target analyte in the sample matrix. This new kinetic calibration method for headspace LPME was successfully used to correct the matrix effects in the BTEX analysis of an orange juice sample. In this study, the headspace LPME techniques were successfully fully automated, for both static and dynamic methods, with the CTC CombiPal autosampler. All operations of headspace LPME, including sample transfer and agitation, filling of extraction solvent, exposing the solvent in the headspace, withdrawing the solvent to syringe and introducing the extraction phase into injector, were autoperformed by the CTC autosampler. The fully automated headspace LPME technique is more convenient and improved the precision and sensitivity of the method. This automated dynamic headspace LPME technique can be also used to obtain the distribution coefficient between the sample matrix (aqueous or another solution) and the extraction phase (1-octanol or another solvent). The distribution coefficient between 1-octanol and orange juice, at 25 degrees C, was obtained with this technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Developments in single-drop microextraction
Psillakis, E., & Kalogerakis, N. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(01)00126-1 · Cited by 373
Cited by
Sarafraz-Yazdi, A., & Amiri, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.10.003 · Cited by 779
Nondestructive Sampling of Living Systems Using in Vivo Solid-Phase Microextraction
Ouyang, G., Vuckovic, D., & Pawliszyn, J. (2011) · Chemical Reviews · doi:10.1021/cr100203t · Cited by 426
Self-citationDevelopments in single-drop microextraction
Xu, L., Basheer, C., & Lee, H. K. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.073 · Cited by 382
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Single drop microextraction—Development, applications and future trends
Jeannot, M. A., Przyjazny, A., & Kokosa, J. M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.10.089 · Cited by 276
Metadata
- Authors
- Ouyang, G., Zhao, W., & Pawliszyn, J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-11-12
- Volume
- 77
- Issue
- 24
- Pages
- 8122-8128
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1992819647
- Cited by
- 81
- References
- 3
- FWCI
- 7.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.