The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Biosensor Based on Self-Assembling Acetylcholinesterase on Carbon Nanotubes for Flow Injection/Amperometric Detection of Organophosphate Pesticides and Nerve Agents
Abstract
A highly sensitive flow injection amperometric biosensor for organophosphate pesticides and nerve agents based on self-assembled acetylcholinesterase (AChE) on a carbon nanotube (CNT)-modified glassy carbon (GC) electrode is described. AChE is immobilized on the negatively charged CNT surface by alternatively assembling a cationic poly(diallyldimethylammonium chloride) (PDDA) layer and an AChE layer. Transmission electron microscopy images confirm the formation of layer-by-layer nanostructures on carboxyl-functionalized CNTs. Fourier transform infrared reflectance spectrum indicates the AChE was immobilized successfully on the CNT/PDDA surface. The unique sandwich-like structure (PDDA/AChE/PDDA) on the CNT surface formed by self-assembling provides a favorable microenvironment to keep the bioactivity of AChE. The electrocatalytic activity of CNT leads to a greatly improved electrochemical detection of the enzymatically generated thiocholine product, including a low oxidation overvoltage (+150 mV), higher sensitivity, and stability. The developed PDDA/AChE/PDDA/CNT/GC biosensor integrated into a flow injection system was used to monitor organophosphate pesticides and nerve agents, such as paraoxon. The sensor performance, including inhibition time and regeneration conditions, was optimized with respect to operating conditions. Under the optimal conditions, the biosensor was used to measure as low as 0.4 pM paraoxon with a 6-min inhibition time. The biosensor had excellent operational lifetime stability with no decrease in the activity of enzymes for more than 20 repeated measurements over a 1-week period. The developed biosensor system is an ideal tool for online monitoring of organophosphate pesticides and nerve agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Helical microtubules of graphitic carbon
Iijima, S. (1991) · Nature · doi:10.1038/354056a0 · Cited by 43,098
Ellman, G. L. (1959) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(59)90090-6 · Cited by 26,311
The United States Department of Agriculture
True, A. C. (1912) · The ANNALS of the American Academy of Political and Social Science · doi:10.1177/000271621204000113 · Cited by 5,113
Carbon‐Nanotube Based Electrochemical Biosensors: A Review
Wang, J. (2005) · Electroanalysis · doi:10.1002/elan.200403113 · Cited by 2,387
A colorimetric method for determining low concentrations of mercaptans
Ellman, G. L. (1958) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(58)90014-6 · Cited by 1,080
Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes
Musameh, M., Wang, J., Merkoci, A., & Lin, Y. (2002) · Electrochemistry Communications · doi:10.1016/s1388-2481(02)00451-4 · Cited by 1,066
Self-citationElectrochemical Sensors Based on Carbon Nanotubes
Zhao, Q., Gan, Z., & Zhuang, Q. (2002) · Electroanalysis · doi:10.1002/elan.200290000 · Cited by 622
Fast Electron Transfer Kinetics on Multiwalled Carbon Nanotube Microbundle Electrodes
Nugent, J. M., Santhanam, K. S. V., Rubio, Á., & Ajayan, P. M. (2001) · Nano Letters · doi:10.1021/nl005521z · Cited by 510
Evidence from Antarctic ice cores for recent increases in snow accumulation
Morgan, V. I., Goodwin, I. D., Etheridget, D. M., & Wookey, C. W. (1991) · Nature · doi:10.1038/354058a0 · Cited by 348
Protein architecture : interfacing molecular assemblies and immobilization biotechnology
LVOV, Y. M., & Möhwald, H. (2000) · Marcel Dekker eBooks · Cited by 316
Cited by
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
Carbon nanotubes for electrochemical biosensing
RIVAS, G., RUBIANES, M., RODRIGUEZ, M., FERREYRA, N., LUQUE, G., PEDANO, M., MISCORIA, S., & PARRADO, C. (2007) · Talanta · doi:10.1016/j.talanta.2007.10.013 · Cited by 554
Electrochemical nanobiosensors
Pumera, M., Sánchez, S., Ichinose, I., & Tang, J. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.11.016 · Cited by 495
Toxicity, monitoring and biodegradation of organophosphate pesticides: A review
Sidhu, G. K., Singh, S., Kumar, V., Dhanjal, D. S., Datta, S., & Singh, J. (2019) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2019.1565554 · Cited by 492
Fundamentals, Applications, and Future Directions of Bioelectrocatalysis
Chen, H., Simoska, O., Lim, K., Grattieri, M., Yuan, M., Dong, F., Lee, Y. S., Beaver, K., Weliwatte, S., Gaffney, E. M., et al. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00472 · Cited by 492
Electrochemical Sensors Based on Carbon Nanotubes
Ahammad, A. J. S., Lee, J.-J., & Rahman, M. A. (2009) · Sensors · doi:10.3390/s90402289 · Cited by 371
Nanomaterials for bio-functionalized electrodes: recent trends
Walcarius, A., Minteer, S. D., Wang, J., Lin, Y., & Merkoçi, A. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20881h · Cited by 366
Self-citationUpdate 1 of: Destruction and Detection of Chemical Warfare Agents
Jang, Y. J., Kim, K., Tsay, O. G., Atwood, D. A., & Churchill, D. G. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00402 · Cited by 360
Biosensors as innovative tools for the detection of food borne pathogens
Arora, P., Sindhu, A., Dilbaghi, N., & Chaudhury, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.06.002 · Cited by 350
Electrochemical biosensors - principles and applications
Pohanka, M., & Skládal, P. (2008) · Journal of Applied Biomedicine · doi:10.32725/jab.2008.008 · Cited by 341
Functionalized carbon nanotubes and nanofibers for biosensing applications
Wang, J., & Lin, Y. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.05.009 · Cited by 289
Self-citationRecent Advances in the Development of Chromophore-Based Chemosensors for Nerve Agents and Phosgene
Chen, L., Wu, D., & Yoon, J. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00816 · Cited by 285
Biosensor Technology for Pesticides—A review
Verma, N., & Bhardwaj, A. (2015) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-015-1489-2 · Cited by 284
Kumar, P., Kim, K.-H., & Deep, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.066 · Cited by 278
Zhang, W., Asiri, A. M., Liu, D., Du, D., & Lin, Y. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.10.007 · Cited by 270
Self-citationDevelopment and Applications of Portable Biosensors
Srinivasan, B., & Tung, S. (2015) · SLAS Technology · doi:10.1177/2211068215581349 · Cited by 262
Nanotechnology-based electrochemical sensors for biomonitoring chemical exposures
Barry, R. C., Lin, Y., Wang, J., Liu, G., & Timchalk, C. A. (2009) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2008.71 · Cited by 73
Self-citation
Metadata
- Authors
- Liu, G., & Lin, Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-01-06
- Volume
- 78
- Issue
- 3
- Pages
- 835-843
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1996422457
- Cited by
- 478
- References
- 13
- FWCI
- 32.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.