The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Liver-Specific Functional Studies in a Microfluidic Array of Primary Mammalian Hepatocytes
Abstract
Nearly half a billion dollars in resources are lost each time a drug candidate is withdrawn from the market by the Food and Drug Administration (FDA) for reasons of liver toxicity. The number of late-phase drug developmental failures due to liver toxicity could potentially be reduced through the use of hepatocyte-based systems capable of modeling the response of in vivo liver tissue to toxic insults. With this article, we report progress toward the goal of realizing an array of primary hepatocytes for use in high-throughput liver toxicity studies. Described herein is the development of a 64 (8 x 8) element array of microfluidic wells capable of supporting micropatterned primary rat hepatocytes in coculture with 3T3-J2 fibroblasts. Each of the wells within the array was continuously perfused with medium and oxygen in a nonaddressable format. The key features of the system design and fabrication are described, including the use of two microfluidic perfusion networks to provide the coculture with an independent and continuous supply of cell culture medium and oxygen. Also described are the fabrication techniques used to selectively pattern hepatocytes and 3T3-J2 fibroblasts within the wells of the array. The functional studies used to demonstrate the synthetic and metabolic capacity of the array are outlined in this article. These studies demonstrate that the hepatocytes contained within the array are capable of continuous, steady-state albumin synthesis (78.4 microg/day, sigma = 3.98 microg/day, N = 8) and urea production (109.8 microg/day, sigma = 11.9 microg/day, N = 8). In the final section of the article, these results are discussed as they relate to the final goal of this research effort, the development of an array of primary hepatocytes for use in physiologically relevant toxicology studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890
Self-citation
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Metadata
- Authors
- Kane, B. J., Zinner, M. J., Yarmush, M. L., & Toner, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-06-08
- Volume
- 78
- Issue
- 13
- Pages
- 4291-4298
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2089704822
- Cited by
- 264
- References
- 1
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liver-Specific Functional Studies in a Microfluidic Array of Primary Mammalian Hepatocytes. https://app.cochat.ai/papers/10.1021/ac051856v
- The paper
- Kane, B. J., Zinner, M. J., Yarmush, M. L., & Toner, M. (2006). Liver-Specific Functional Studies in a Microfluidic Array of Primary Mammalian Hepatocytes. Analytical Chemistry. https://doi.org/10.1021/ac051856v
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.