Robust Algorithm for Alignment of Liquid Chromatography−Mass Spectrometry Analyses in an Accurate Mass and Time Tag Data Analysis Pipeline
The DOI matches its Crossref record.
Abstract
Liquid chromatography coupled to mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS) has become a standard technique for analyzing complex peptide mixtures to determine composition and relative abundance. Several high-throughput proteomics techniques attempt to combine complementary results from multiple LC-MS and LC-MS/MS analyses to provide more comprehensive and accurate results. To effectively collate and use results from these techniques, variations in mass and elution time measurements between related analyses need to be corrected using algorithms designed to align the various types of data: LC-MS/MS versus LC-MS/MS, LC-MS versus LC-MS/MS, and LC-MS versus LC-MS. Described herein are new algorithms referred to collectively as liquid chromatography-based mass spectrometric warping and alignment of retention times of peptides (LCMSWARP), which use a dynamic elution time warping approach similar to traditional algorithms that correct for variations in LC elution times using piecewise linear functions. LCMSWARP is compared to the equivalent approach based upon linear transformation of elution times. LCMSWARP additionally corrects for temporal drift in mass measurement accuracies. We also describe the alignment of LC-MS results and demonstrate their application to the alignment of analyses from different chromatographic systems, showing the suitability of the present approach for more complex transformations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantitative mass spectrometry in proteomics: a critical review
Bantscheff, M., Schirle, M., Sweetman, G., Rick, J., & Kuster, B. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1486-6 · Cited by 1,669
Data processing for mass spectrometry-based metabolomics
Katajamaa, M., & Orešič, M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.021 · Cited by 616
A high-resolution mass spectrometer to measure atmospheric ion composition
Junninen, H., Ehn, M., Petäjä, T., Luosujärvi, L., Kotiaho, T., Kostiainen, R., Rohner, U., Gonin, M., Fuhrer, K., Kulmala, M., et al. (2010) · Atmospheric Measurement Techniques · doi:10.5194/amt-3-1039-2010 · Cited by 567
Proteomics: a pragmatic perspective
Mallick, P., & Kuster, B. (2010) · Nature Biotechnology · doi:10.1038/nbt.1658 · Cited by 430
Diamond, D. L., Syder, A. J., Jacobs, J. M., Sorensen, C. M., Walters, K.-A., Proll, S. C., McDermott, J. E., Gritsenko, M. A., Zhang, Q., Zhao, R., et al. (2010) · PLoS Pathogens · doi:10.1371/journal.ppat.1000719 · Cited by 412
Self-citationDengue Virus Infection Perturbs Lipid Homeostasis in Infected Mosquito Cells
Perera, R., Riley, C., Isaac, G., Hopf-Jannasch, A. S., Moore, R. J., Weitz, K. W., Pasa-Tolic, L., Metz, T. O., Adamec, J., & Kuhn, R. J. (2012) · PLoS Pathogens · doi:10.1371/journal.ppat.1002584 · Cited by 356
Manes, N. P., Estep, R. D., Mottaz, H. M., Moore, R. J., Clauss, T. R. W., Monroe, M. E., Du, X., Adkins, J. N., Wong, S. W., & Smith, R. D. (2008) · Journal of Proteome Research · doi:10.1021/pr070432+ · Cited by 103
Self-citationZhou, M., Paša-Tolić, L., & Stenoien, D. L. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00694 · Cited by 39
Metadata
- Authors
- Jaitly, N., Monroe, M. E., Petyuk, V. A., Clauss, T. R. W., Adkins, J. N., & Smith, R. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-10-04
- Volume
- 78
- Issue
- 21
- Pages
- 7397-7409
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2073470877
- Cited by
- 157
- References
- 0
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.