The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Automatic Selection of Optimal Savitzky−Golay Smoothing
Abstract
A method to select the optimal window size of the Savitzky-Golay (SG) algorithm is presented. The approach is based on a comparison of the fitting residuals (i.e., the differences between the input signal and the smoothed signal) with the noise of the instrument. The window size that yields an autocorrelation of the residuals closest to the autocorrelation of the noise of the instrument is considered optimal. The method is applied in two steps. In a first step, the lag-one autocorrelation value of the noise of the instrument is computed through the study of a blank signal. In a second step, the SG algorithm is applied to "smooth" the signal using different window sizes. The method was applied to data from NMR, chromatography, and mass spectrometry and was shown to be robust. It finds the optimal window size for different signal features. This allows the method to be used in an unsupervised way, embedded in a more complex algorithm in which smoothing and/or differentiation of signals is required, provided that the lag-one autocorrelation value of the instrument noise does not change.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Cited by
Deep learning for vibrational spectral analysis: Recent progress and a practical guide
Yang, J., Xu, J., Zhang, X., Wu, C., Lin, T., & Ying, Y. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.06.012 · Cited by 299
Liu, X., Qiao, S., & Ma, Y. (2022) · Optics Express · doi:10.1364/oe.446294 · Cited by 97
Metadata
- Authors
- Vivó-Truyols, G., & Schoenmakers, P. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-05-23
- Volume
- 78
- Issue
- 13
- Pages
- 4598-4608
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2124830968
- Cited by
- 177
- References
- 1
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.