CoChat

Enhancement of Amino Acid Detection and Quantification by Electrospray Ionization Mass Spectrometry

Yang, Wen-Chu, Mirzaei, Hamid, Liu, Xiuping, Regnier, Fred E. · 2006 · Analytical Chemistry
Cited by 137

The DOI matches its Crossref record.

Abstract

A new strategy for amino acid analysis is reported involving derivatization with an N-hydroxysuccinimide ester of N-alkylnicotinic acid (Cn-NA-NHS) followed by reversed-phase chromatography and electrospray ionization mass spectrometry (RPC-MS). Detection sensitivity increased as the N-alkyl chain length of the nicotinic acid derivatizing agent was increased from 1 to 4. N-Acylation of amino acids with the Cn-NA-NHS reagents in water produced a stable product in roughly 1 min using a 4-fold molar excess of derivatizing agent in 0.1 M sodium borate buffer at pH values ranging from 8.5 to 10. Some O-acylation of tyrosine was also observed, but the product hydrolyzed within a few minutes at pH 10. The cystine product also degraded slowly over the course of a few days from reduction of the disulfide bond to form cysteine. The retention time of Cn-NA derivatized amino acids was lengthened in reversed-phase chromatography to the extent that polar amino acids were retained beyond the solvent peak, particularly in the cases of the C3-NA and C4-NA derivatives. Complete resolution of 18 amino acids was achieved in 28 min using the C4-NA-NHS reagent. Compared to N-acylation with benzoic acid, derivatization with C4-NA-NHS increased MS detection sensitivity 6-80-fold. This was attributed to the surfactant properties of the Cn-NA-NHS reagents. The quaternary amine increased the charge on amino acid conjugates while the presence of an adjacent alkyl chain further increased ionization efficiency by apparently enhancing amino acid migration to the surface of electrospray droplets. Further modification of the Cn-NA-NHS reagents with deuterium was used to prepare coded sets of derivatizing agents. These coding agents were used to differentially code samples and after mixing carry out comparative concentration measurements between samples using extracted ion chromatograms to estimate relative peak areas of derivatized amino acids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac0600510

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Yang, W.-C., Mirzaei, H., Liu, X., & Regnier, F. E.
Venue
Analytical Chemistry
Published
2006-05-17
Volume
78
Issue
13
Pages
4702-4708
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1989155308
Cited by
137
References
0
FWCI
3.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.