The DOI matches its Crossref record.
High-Performance Carbon Composite Electrode Based on an Ionic Liquid as a Binder
Abstract
Ionic liquid, n-octylpyridinum hexafluorophosphate (OPFP) has been used to fabricate a new carbon composite electrode with very attractive electrochemical behavior. This type of carbon electrode has been constructed using graphite mixed with OPFP as the binder. The electrode has combined advantages of edge plane characteristics of carbon nanotubes and edge plane pyrolytic graphite electrodes together with the low cost of carbon paste electrodes and robustness of metallic electrodes. It provides a remarkable increase in the rate of electron transfer of different organic and inorganic electroactive compounds and offers a marked decrease in the overvoltage for biomolecules such as NADH, dopamine, and ascorbic acid. It also circumvents NADH surface fouling effects as well as furnishing higher current density for a wide range of compounds tested. Depending on the choice of the electrolyte, the electrode can have the ion-exchange property and adsorptive characteristics of clay-modified electrodes. The proposed electrode thus allows sensitive, low-potential, simple, low-cost, and stable electrochemical sensing of biomolecules and other electroactive compounds. Scanning electron microscopy images indicate significant improvement in the microstructure of the proposed electrode compared to carbon paste electrodes. Such abilities promote new opportunities for a wide range of electrochemical and biosensing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advanced Carbon Electrode Materials for Molecular Electrochemistry
McCreery, R. L. (2008) · Chemical Reviews · doi:10.1021/cr068076m · Cited by 2,729
Ionic liquids in analytical chemistry
Sun, P., & Armstrong, D. W. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.12.007 · Cited by 727
Recent trends in carbon nanomaterial-based electrochemical sensors for biomolecules: A review
Yang, C., Denno, M. E., Pyakurel, P., & Venton, B. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.05.049 · Cited by 577
Application of ionic liquids in electrochemical sensing systems
Shiddiky, M. J. A., & Torriero, A. A. J. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.064 · Cited by 408
A review on electrodes modified with ionic liquids
Opallo, M., & Lesniewski, A. (2011) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2011.01.008 · Cited by 351
Metadata
- Authors
- Maleki, N., Safavi, A., & Tajabadi, F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-04-26
- Volume
- 78
- Issue
- 11
- Pages
- 3820-3826
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2018688487
- Cited by
- 504
- References
- 0
- FWCI
- 42.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Performance Carbon Composite Electrode Based on an Ionic Liquid as a Binder. https://app.cochat.ai/papers/10.1021/ac060070+
- The paper
- Maleki, N., Safavi, A., & Tajabadi, F. (2006). High-Performance Carbon Composite Electrode Based on an Ionic Liquid as a Binder. Analytical Chemistry. https://doi.org/10.1021/ac060070%2B
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.