CoChat

Tetrabutylammonium-Induced Coacervation in Vesicular Solutions of Alkyl Carboxylic Acids for the Extraction of Organic Compounds

Ruiz, Francisco-Javier, Rubio, Soledad, Pérez-Bendito, Dolores · 2006 · Analytical Chemistry
Cited by 118

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The potential of the tetrabutylammonium-induced liquid-liquid-phase separation in alkyl carboxylic acid vesicular solutions for the extraction of organic compounds prior to liquid chromatography was examined for the first time. The behavior of the coacervates yielded from octanoic to oleic acids as a function of the pH and salts was investigated. The time required for phase separation depended on the length of the carboxylic acid alkyl chain and the experimental procedure (i.e., standing, sonication, centrifugation, stirring, etc.). Theoretical preconcentration factors were a function of both surfactant concentration and the length of the alkyl chain, and they greatly surpassed those obtained with other surfactant-mediated separations (e.g., surfactant-rich phases from dodecanesulfonic acid or Triton X-114). Parameters affecting the extraction efficiency were assessed. Analytes in a wide polarity/charge range, (e.g., PAHs, surfactants, chlorophenols, bisphenols, phthalates, herbicides, amines, dyes, and photographic developers) were extracted with high efficiencies on the basis of the different types of interactions that the vesicular coacervates can establish (i.e., hydrophobic and ionic interactions, hydrogen bonds, and formation of mixed aggregates). The coacervates were compatible with the chromatographic determination of analytes following UV or MS detection. Their suitability for working under real conditions was checked by applying them to the extraction of nonionic surfactants [alkylphenol ethoxylates (octyl and nonyl) and alcohol ethoxylates (C12-C16)] from raw and treated sewage and to river water samples. Analytes in the coacervate were separated and quantified by liquid chromatography-ion trap mass spectrometry. No cleanup steps were necessary. Recoveries of the target compounds in the environmental water samples ranged from 89 to 103%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac060427+

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 118

Metadata

Authors
Ruiz, F.-J., Rubio, S., & Pérez-Bendito, D.
Venue
Analytical Chemistry
Published
2006-09-12
Volume
78
Issue
20
Pages
7229-7239
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1970613890
Cited by
118
References
6
FWCI
5.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tetrabutylammonium-Induced Coacervation in Vesicular Solutions of Alkyl Carboxylic Acids for the Extraction of Organic Compounds. https://app.cochat.ai/papers/10.1021/ac060427+
The paper
Ruiz, F.-J., Rubio, S., & Pérez-Bendito, D. (2006). Tetrabutylammonium-Induced Coacervation in Vesicular Solutions of Alkyl Carboxylic Acids for the Extraction of Organic Compounds. Analytical Chemistry. https://doi.org/10.1021/ac060427%2B

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.