The DOI matches its Crossref record.
Multiple Label-Free Detection of Antigen−Antibody Reaction Using Localized Surface Plasmon Resonance-Based Core−Shell Structured Nanoparticle Layer Nanochip
Abstract
In this research, a localized surface plasmon resonance (LSPR)-based bioanalysis method for developing multiarray optical nanochip suitable for screening bimolecular interactions is described. LSPR-based label-free monitoring enables to solve the problems of conventional methods that require large sample volumes and time-consuming labeling procedures. We developed a multiarray LSPR-based nanochip for the label-free detection of proteins. The multiarray format was constructed by a core-shell-structured nanoparticle layer, which provided 300 nanospots on the sensing surface. Antibodies were immobilized onto the nanospots using their interaction with Protein A. The concentrations of antigens were determined from the peak absorption intensity of the LSPR spectra. We demonstrated the capability of the array measurement using immunoglobulins (IgA, IgD, IgG, IgM), C-reactive protein, and fibrinogen. The detection limit of our label-free method was 100 pg/mL. Our nanochip is readily transferable to monitor the interactions of other biomolecules, such as whole cells or receptors, with a massively parallel detection capability in a highly miniaturized package. We anticipate that the direct label-free optical immunoassay of proteins reported here will revolutionize clinical diagnosis and accelerate the development of hand-held and user-friendly point-of-care devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Localized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Biofunctionalization of Multiplexed Silicon Photonic Biosensors
Puumala, L. S., Grist, S. M., Morales, J. M., Bickford, J. R., Chrostowski, L., Shekhar, S., & Cheung, K. C. (2022) · Biosensors · doi:10.3390/bios13010053 · Cited by 55
Phase-space modeling of solid-state plasmas: A journey from classical to quantum
Manfredi, G., Hervieux, P.-A., & Hurst, J. (2019) · Reviews of Modern Plasma Physics · doi:10.1007/s41614-019-0034-0 · Cited by 38
Fluid descriptions of quantum plasmas
Manfredi, G., Hervieux, P.-A., & Hurst, J. (2021) · Reviews of Modern Plasma Physics · doi:10.1007/s41614-021-00056-y · Cited by 29
Metadata
- Authors
- Endo, T., Kerman, K., Nagatani, N., Hiepa, H. M., Kim, D.-K., Yonezawa, Y., Nakano, K., & Tamiya, E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-07-22
- Volume
- 78
- Issue
- 18
- Pages
- 6465-6475
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2093816239
- Cited by
- 349
- References
- 0
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiple Label-Free Detection of Antigen−Antibody Reaction Using Localized Surface Plasmon Resonance-Based Core−Shell Structured Nanoparticle Layer Nanochip. https://app.cochat.ai/papers/10.1021/ac0608321
- The paper
- Endo, T., Kerman, K., Nagatani, N., Hiepa, H. M., Kim, D.-K., Yonezawa, Y., Nakano, K., & Tamiya, E. (2006). Multiple Label-Free Detection of Antigen−Antibody Reaction Using Localized Surface Plasmon Resonance-Based Core−Shell Structured Nanoparticle Layer Nanochip. Analytical Chemistry. https://doi.org/10.1021/ac0608321
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.