The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Multiple Label-Free Detection of Antigen−Antibody Reaction Using Localized Surface Plasmon Resonance-Based Core−Shell Structured Nanoparticle Layer Nanochip
Abstract
In this research, a localized surface plasmon resonance (LSPR)-based bioanalysis method for developing multiarray optical nanochip suitable for screening bimolecular interactions is described. LSPR-based label-free monitoring enables to solve the problems of conventional methods that require large sample volumes and time-consuming labeling procedures. We developed a multiarray LSPR-based nanochip for the label-free detection of proteins. The multiarray format was constructed by a core-shell-structured nanoparticle layer, which provided 300 nanospots on the sensing surface. Antibodies were immobilized onto the nanospots using their interaction with Protein A. The concentrations of antigens were determined from the peak absorption intensity of the LSPR spectra. We demonstrated the capability of the array measurement using immunoglobulins (IgA, IgD, IgG, IgM), C-reactive protein, and fibrinogen. The detection limit of our label-free method was 100 pg/mL. Our nanochip is readily transferable to monitor the interactions of other biomolecules, such as whole cells or receptors, with a massively parallel detection capability in a highly miniaturized package. We anticipate that the direct label-free optical immunoassay of proteins reported here will revolutionize clinical diagnosis and accelerate the development of hand-held and user-friendly point-of-care devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A molecular ruler based on plasmon coupling of single gold and silver nanoparticles
Sönnichsen, C., Reinhard, B. M., Liphardt, J., & Alivisatos, A. P. (2005) · Nature Biotechnology · doi:10.1038/nbt1100 · Cited by 1,523
Nath, N., & Chilkoti, A. (2002) · Analytical Chemistry · doi:10.1021/ac015657x · Cited by 918
Nath, N., & Chilkoti, A. (2004) · Analytical Chemistry · doi:10.1021/ac049741z · Cited by 514
Yonzon, C. R., Jeoung, E., Zou, S., Schatz, G. C., Mrksich, M., & Van Duyne, R. P. (2004) · Journal of the American Chemical Society · doi:10.1021/ja047118q · Cited by 494
Prasad, P. N. (2004) · Wiley eBooks · doi:10.1002/0471670251 · Cited by 469
Biosensing Based on Light Absorption of Nanoscaled Gold and Silver Particles
Frederix, F., Friedt, J.-M., Choi, K.-H., Laureyn, W., Campitelli, A., Mondelaers, D., Maes, G., & Borghs, G. (2003) · Analytical Chemistry · doi:10.1021/ac0346609 · Cited by 381
Endo, T., Kerman, K., Nagatani, N., Takamura, Y., & Tamiya, E. (2005) · Analytical Chemistry · doi:10.1021/ac0513459 · Cited by 313
Self-citationWegner, G. J., Lee, H. J., & Corn, R. M. (2002) · Analytical Chemistry · doi:10.1021/ac025922u · Cited by 262
Workman, Koch, M., & Veltkamp, D. (2005) · Analytical Chemistry · doi:10.1021/ac050620o · Cited by 203
Cap-shaped gold nanoparticles for an optical biosensor
Himmelhaus, M., & Takei, H. (2000) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00393-7 · Cited by 191
Label Free Colorimetric Biosensing Using Nanoparticles
Nath, N., & Chilkoti, A. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000031819.45448.dc · Cited by 171
Endo, T., Yamamura, S., Nagatani, N., Morita, Y., Takamura, Y., & Tamiya, E. (2005) · Science and Technology of Advanced Materials · doi:10.1016/j.stam.2005.03.019 · Cited by 133
Self-citationScreening antibody–antigen interactions in parallel using Biacore A100
Säfsten, P., Klakamp, S. L., Drake, A. W., Karlsson, R., & Myszka, D. G. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.01.041 · Cited by 112
Global approaches to protein–protein interactions
Drewes, G., & Bouwmeester, T. (2003) · Current Opinion in Cell Biology · doi:10.1016/s0955-0674(03)00005-x · Cited by 110
Protein Microarrays: Challenges and Promises
Talapatra, A., Rouse, R. J. D., & Hardiman, G. (2002) · Pharmacogenomics · doi:10.1517/14622416.3.4.527 · Cited by 87
Matsubara, Y., Kerman, K., Kobayashi, M., Yamamura, S., Morita, Y., Takamura, Y., & Tamiya, E. (2004) · Analytical Chemistry · doi:10.1021/ac0497149 · Cited by 73
Self-citationDimensionality is the issue: use of photoaptamers in protein microarrays
Petach, H. H., & Gold, L. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00329-4 · Cited by 72
Timperman, A. T., & Aebersold, R. H. (2000) · Analytical Chemistry · doi:10.1021/ac000305w · Cited by 29
Cited by
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Localized Surface Plasmon Resonance Sensors
Mayer, K. M., & Hafner, J. H. (2011) · Chemical Reviews · doi:10.1021/cr100313v · Cited by 4,350
Localized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Sepúlveda, B., Angelomé, P. C., Lechuga, L. M., & Liz-Marzán, L. M. (2009) · Nano Today · doi:10.1016/j.nantod.2009.04.001 · Cited by 1,023
Metadata
- Authors
- Endo, T., Kerman, K., Nagatani, N., Hiepa, H. M., Kim, D.-K., Yonezawa, Y., Nakano, K., & Tamiya, E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-07-22
- Volume
- 78
- Issue
- 18
- Pages
- 6465-6475
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2093816239
- Cited by
- 349
- References
- 18
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.