The DOI matches its Crossref record.
Label-Free Biosensing by Surface Plasmon Resonance of Nanoparticles on Glass: Optimization of Nanoparticle Size
Abstract
The unique optical properties of noble metal nanoparticles have been used to design a label-free biosensor in a chip format. In this paper, we demonstrate that the size of gold nanoparticles significantly affects the sensitivity of the biosensor. Gold nanoparticles with diameters in the range of 12-48 nm were synthesized in solution and sensor chips were fabricated by chemisorption of these nanoparticles on amine-functionalized glass. Sensors fabricated from 39-nm-diameter gold nanoparticles exhibited maximum sensitivity to the change of the bulk refractive index and the largest "analytical volume", defined as the region around the nanoparticle within which a change in refractive index causes a change in the optical properties of the immobilized nanoparticles. The detection limit for streptavidin-biotin binding of a sensor fabricated from 39-nm-diameter nanoparticles was 20-fold better than a previously reported sensor fabricated from 13-nm-diameter gold nanoparticles. We also discuss several other factors that could improve the performance of the next generation of these immobilized metal nanoparticle sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Localized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
Label-free optical biosensors for food and biological sensor applications
Khansili, N., Rattu, G., & Krishna, P. M. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.03.004 · Cited by 328
Label-Free Plasmonic Detection of Biomolecular Binding by a Single Gold Nanorod
Nusz, G. J., Marinakos, S. M., Curry, A. C., Dahlin, A., Höök, F., Wax, A., & Chilkoti, A. (2008) · Analytical Chemistry · doi:10.1021/ac7017348 · Cited by 296
Self-citationAmendola, V., & Meneghetti, M. (2007) · Journal of Materials Chemistry · doi:10.1039/b709621f · Cited by 150
Dependence of gold nanoparticle production on pulse duration by laser ablation in liquid media
Riabinina, D., Chaker, M., & Margot, J. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/13/135603 · Cited by 77
Metadata
- Authors
- Nath, N., & Chilkoti, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-08-05
- Volume
- 76
- Issue
- 18
- Pages
- 5370-5378
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1995981635
- Cited by
- 514
- References
- 0
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Label-Free Biosensing by Surface Plasmon Resonance of Nanoparticles on Glass: Optimization of Nanoparticle Size. https://app.cochat.ai/papers/10.1021/ac049741z
- The paper
- Nath, N., & Chilkoti, A. (2004). Label-Free Biosensing by Surface Plasmon Resonance of Nanoparticles on Glass: Optimization of Nanoparticle Size. Analytical Chemistry. https://doi.org/10.1021/ac049741z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.