The DOI matches its Crossref record.
Chemically Etched Open Tubular and Monolithic Emitters for Nanoelectrospray Ionization Mass Spectrometry
Open accessAbstract
We have developed a new procedure for fabricating fused-silica emitters for electrospray ionization-mass spectrometry (ESI-MS) in which the end of a bare fused-silica capillary is immersed into aqueous hydrofluoric acid, and water is pumped through the capillary to prevent etching of the interior. Surface tension causes the etchant to climb the capillary exterior, and the etch rate in the resulting meniscus decreases as a function of distance from the bulk solution. Etching continues until the silica touching the hydrofluoric acid reservoir is completely removed, essentially stopping the etch process. The resulting emitters have no internal taper, making them much less prone to clogging compared to, e.g., pulled emitters. The high aspect ratios and extremely thin walls at the orifice facilitate very low flow rate operation; stable ESI-MS signals were obtained for model analytes from 5-microm-diameter emitters at a flow rate of 5 nL/min with a high degree of interemitter reproducibility. In extensive evaluation, the etched emitters were found to enable approximately four times as many LC-MS analyses of proteomic samples before failing compared with conventional pulled emitters. The fabrication procedure was also employed to taper the ends of polymer monolith-containing silica capillaries for use as ESI emitters. In contrast to previous work, the monolithic material protrudes beyond the fused-silica capillaries, improving the monolith-assisted electrospray process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fermentation, Hydrogen, and Sulfur Metabolism in Multiple Uncultivated Bacterial Phyla
Wrighton, K. C., Thomas, B. C., Sharon, I., Miller, C. S., Castelle, C. J., VerBerkmoes, N. C., Wilkins, M. J., Hettich, R. L., Lipton, M. S., Williams, K. H., et al. (2012) · Science · doi:10.1126/science.1224041 · Cited by 661
Wang, Y., Yang, F., Gritsenko, M. A., Wang, Y., Clauss, T., Liu, T., Shen, Y., Monroe, M. E., Lopez‐Ferrer, D., Reno, T., et al. (2011) · PROTEOMICS · doi:10.1002/pmic.201000722 · Cited by 598
Self-citationYu, J., Liberton, M., Cliften, P. F., Head, R. D., Jacobs, J. M., Smith, R. D., Koppenaal, D. W., Brand, J. J., & Pakrasi, H. B. (2015) · Scientific Reports · doi:10.1038/srep08132 · Cited by 370
Self-citationLabel-free quantification in ion mobility–enhanced data-independent acquisition proteomics
Distler, U., Kuharev, J., Navarro, P., & Tenzer, S. (2016) · Nature Protocols · doi:10.1038/nprot.2016.042 · Cited by 329
The ion funnel: Theory, implementations, and applications
Kelly, R. T., Tolmachev, A. V., Page, J. S., Tang, K., & Smith, R. D. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20232 · Cited by 280
Self-citationIonization and transmission efficiency in an electrospray ionization—mass spectrometry interface
Page, J. S., Kelly, R. T., Tang, K., & Smith, R. D. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.05.018 · Cited by 265
Self-citationWang, C., Lee, C. S., Smith, R. D., & Tang, K. (2012) · Analytical Chemistry · doi:10.1021/ac302616m · Cited by 38
Self-citationMa, F., Huang, X., Ke, M., Shi, Q., Chen, Q., Shi, C., Zhang, J., Zhang, X., & Yu, H. (2017) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.7b01685 · Cited by 34
Hollerbach, A. L., Lin, V. S., Ibrahim, Y. M., Ewing, R. G., Metz, T. O., & Rodda, K. E. (2024) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.4c00200 · Cited by 18
Metadata
- Authors
- Kelly, R. T., Page, J. S., Luo, Q., Moore, R. J., Orton, D. J., Tang, K., & Smith, R. D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-10-18
- Volume
- 78
- Issue
- 22
- Pages
- 7796-7801
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1965993495
- Cited by
- 240
- References
- 0
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.