Cited by 38Microfluidic and Capillary Electrophoresis ApplicationsMass Spectrometry Techniques and ApplicationsAdvanced Proteomics Techniques and Applications

Ultrasensitive Sample Quantitation via Selected Reaction Monitoring Using CITP/CZE–ESI-Triple Quadrupole MS

Open access
Wang, Chenchen, Lee, Cheng S., Smith, Richard D., Tang, Keqi·2012·Analytical Chemistry

Abstract

We demonstrate the direct coupling of transient capillary isotachophoresis/capillary zone electrophoresis (CITP/CZE) with a high-sensitivity triple quadrupole mass spectrometer operating in selected reaction monitoring (SRM) mode for sample quantitation. The capability of CITP/CZE for in situ sample enrichment and separation has been shown to significantly improve the analytical figures of merit. A linear dynamic range spanning 4 orders of magnitude was observed. An average signal-to-noise ratio (S/N) of 49.6 was observed for 50 amol of targeted peptide in the presence of a complex and much more abundant bovine serum albumin (BSA) digest. Correlation of variation (CV) of <10% for peak area was measured from triplicate sample analyses at 50 pM peptide concentration, showing good reproducibility of this online CITP/CZE-SRM mass spectrometry (MS) platform, and with limit of quantitation (LOQ) demonstrated to be well below 50 pM.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac302616m

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. [8]Ravelo-Perez LM Asensio-Ramos M Hernandez-Borges J Rodriguez-Delgado MA Electrophoresis 2009 30 1624 19360778
  2. [36]Kuhr WG Anal Chem 1990 62 403R 20527859

Cited by

Sorted by citations

Authors
Wang, C., Lee, C. S., Smith, R. D., & Tang, K.
Affiliations
  • University of Maryland, College Park (US)
  • Pacific Northwest National Laboratory (US)
Corresponding author
Tang, Keqi
Venue
Analytical Chemistry
Published
2012-11-20
Volume
84
Issue
23
Pages
10395-10403
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2086757556
Cited by
38
References
38
Citations by year
2024: 2 · 2020: 5 · 2019: 1 · 2018: 5 · 2017: 7 · 2016: 4 · 2015: 2 · 2014: 7 · 2013: 4 · 2012: 1
FWCI
2.55
Type
journal article
Language
en
Open access
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • U.S. Department of Energy
  • Battelle
  • National Institutes of Health (5p41gm103493-20)
  • National Cancer Institute (R21CA143177, R33CA155252)
  • National Institute of General Medical Sciences (8 P41 GM103493-10, R21GM103536, P41-GM103493)
  • Pacific Northwest National Laboratory
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
Keywords
capillary isotachophoresis, capillary zone electrophoresis, multiple reaction monitoring, triple quadrupole mass spectrometry, peptide quantification, detection limit, signal-to-noise ratio
MeSH terms
Animals, Cattle, Humans, Peptide Fragments, Serum Albumin, Bovine, Reproducibility of Results, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization, Isotachophoresis, Signal-To-Noise Ratio

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review