CE-Microreactor-CE-MS/MS for Protein Analysis
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We present a proof-of-principle for a fully automated bottom-up approach to protein characterization. Proteins are first separated by capillary electrophoresis. A pepsin microreactor is incorporated into the distal end of this capillary. Peptides formed in the reactor are transferred to a second capillary, where they are separated by capillary electrophoresis and characterized by mass spectrometry. While peptides generated from one digestion are being separated in the second capillary, the next protein fraction undergoes digestion in the microreactor. The migration time in the first dimension capillary is characteristic of the protein while migration time in the second dimension is characteristic of the peptide. Spot capacity for the two-dimensional separation is 590. A MS/MS analysis of a mixture of cytochrome c and myoglobin generated Mascot MOWSE scores of 107 for cytochrome c and 58 for myoglobin. The sequence coverages were 48% and 22%, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Cited by
Metal–organic framework gels and monoliths
Hou, J., Sapnik, A. F., & Bennett, T. D. (2020) · Chemical Science · doi:10.1039/c9sc04961d · Cited by 331
Wojcik, R., Dada, O. O., Sadilek, M., & Dovichi, N. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4672 · Cited by 234
Self-citationCapillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
Nguyen, T. T. T. N., Petersen, N. J., & Rand, K. D. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.07.002 · Cited by 33
Mou, S., Sun, L., & Dovichi, N. J. (2013) · Analytical Chemistry · doi:10.1021/ac402858a · Cited by 22
Self-citation
Metadata
- Authors
- Schoenherr, R. M., Ye, M., Vannatta, M., & Dovichi, N. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-02-13
- Volume
- 79
- Issue
- 6
- Pages
- 2230-2238
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2080750234
- Cited by
- 98
- References
- 1
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CE-Microreactor-CE-MS/MS for Protein Analysis. https://app.cochat.ai/papers/10.1021/ac061638h
- The paper
- Schoenherr, R. M., Ye, M., Vannatta, M., & Dovichi, N. J. (2007). CE-Microreactor-CE-MS/MS for Protein Analysis. Analytical Chemistry. https://doi.org/10.1021/ac061638h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.