Accurate Determination of Peptide Phosphorylation Stoichiometry Via Automated Diagonal Capillary Electrophoresis Coupled with Mass Spectrometry: Proof of Principle
Open accessAbstract
While reversible protein phosphorylation plays an important role in many cellular processes, simple and reliable measurement of the stoichiometry of phosphorylation can be challenging. This measurement is confounded by differences in the ionization efficiency of phosphorylated and unphosphorylated sites during analysis by mass spectrometry. Here, we demonstrate diagonal capillary electrophoresis-mass spectrometry for the accurate determination of this stoichiometry. Diagonal capillary electrophoresis is a two-dimensional separation method that incorporates an immobilized alkaline phosphatase microreactor at the distal end of the first capillary and employs identical electrophoretic separation modes in both dimensions. The first dimension is used to separate a mixture of the phosphorylated and unphosphorylated forms of a peptide. Fractions are parked in the reactor where they undergo complete dephosphorylation. The products are then periodically transferred to the second capillary and analyzed by mass spectrometry (MS). Because the phosphorylated and unphosphorylated forms differ in charge, they are well resolved in the first dimension separation. Because the unphosphorylated and dephosphorylated peptides are identical, there is no bias in ionization efficiency, and phosphorylation stoichiometry can be determined by the ratio of the signal of the two forms. A calibration curve was generated from mixtures of a phosphorylated standard peptide and its unphosphorylated form, prepared in a bovine serum albumin tryptic digest. This proof of principle experiment demonstrated a linear response across nearly 2 orders of magnitude in stoichiometry.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Post-translational phosphorylation plays critical roles in biological systems and can influence the electrophoretic mobility of peptides.
“Post-translational phosphorylation plays critical roles in biological systems83 and it can also influence the electrophoretic mobility of peptides.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [83]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683 · see citing works
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401 · see citing works
Global, In Vivo, and Site-Specific Phosphorylation Dynamics in Signaling Networks
Olsen, J. V., Blagoev, B., Gnad, F., Maček, B., Kumar, C., Mortensen, P., & Mann, M. (2006) · Cell · doi:10.1016/j.cell.2006.09.026 · Cited by 3,484 · see citing works
Thompson, A., Schäfer, J., Kuhn, K., Kienle, S., Schwarz, J., Schmidt, G., Neumann, T., & Hamon, C. (2003) · Analytical Chemistry · doi:10.1021/ac0262560 · Cited by 2,386 · see citing works
The origins of protein phosphorylation
Cohen, P. (2002) · Nature Cell Biology · doi:10.1038/ncb0502-e127 · Cited by 1,147 · see citing works
Analysis of protein phosphorylation using mass spectrometry: deciphering the phosphoproteome
Mann, M., Ong, S. E., Grønborg, M., Steen, H., Jensen, O. N., & Pandey, A. (2002) · Trends in biotechnology · doi:10.1016/s0167-7799(02)01944-3 · Cited by 901 · see citing works
A practical recipe for stable isotope labeling by amino acids in cell culture (SILAC)
Ong, S., & Mann, M. (2006) · Nature Protocols · doi:10.1038/nprot.2006.427 · Cited by 898 · see citing works
Brown, J., & Hartley, B. S. (1966) · Biochemical Journal · doi:10.1042/bj1010214 · Cited by 449 · see citing works
Mass Spectrometry–Based Proteomics and Network Biology
Bensimon, A., Heck, A. J. R., & Aebersold, R. H. (2012) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-072909-100424 · Cited by 407 · see citing works
Global and Site-Specific Quantitative Phosphoproteomics: Principles and Applications
Maček, B., Mann, M., & Olsen, J. V. (2008) · The Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pharmtox.011008.145606 · Cited by 385 · see citing works
A large-scale method to measure absolute protein phosphorylation stoichiometries
Wu, R., Haas, W., Dephoure, N., Huttlin, E. L., Zhai, B., Sowa, M. E., & Gygi, S. P. (2011) · Nature Methods · doi:10.1038/nmeth.1636 · Cited by 277 · see citing works
Wojcik, R., Dada, O. O., Sadilek, M., & Dovichi, N. J. (2010) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4672 · Cited by 234 · see citing works
Self-citationChromatographic Isolation of Methionine-containing Peptides for Gel-free Proteome Analysis
Gevaert, K., Damme, J. V., Goethals, M., et al. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200061-mcp200 · Cited by 229 · see citing works
Wu, R., Dephoure, N., Haas, W., Huttlin, E. L., Zhai, B., Sowa, M. E., & Gygi, S. P. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.009654 · Cited by 175 · see citing works
Li, Y., Champion, M. M., Sun, L., Champion, P. A. D., Wojcik, R., & Dovichi, N. J. (2012) · Analytical Chemistry · doi:10.1021/ac202899p · Cited by 128 · see citing works
Self-citationCE-Microreactor-CE-MS/MS for Protein Analysis
Schoenherr, R. M., Ye, M., Vannatta, M. W., & Dovic̀hi, N. J. (2007) · Analytical Chemistry · doi:10.1021/ac061638h · Cited by 98 · see citing works
Self-citationPalm, A. K., & Novotný, M. V. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1500 · Cited by 96 · see citing works
Domański, D., Murphy, L. C., & Borchers, C. H. (2010) · Analytical Chemistry · doi:10.1021/ac1005553 · Cited by 69 · see citing works
Protein phosphorylation analysis by electrospray ionization-mass spectrometry
Resing, K. A., & Ahn, N. G. (1997) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(97)83005-4 · Cited by 64 · see citing works
Li, Y., Wojcik, R., Dovic̀hi, N. J., & Champion, M. M. (2012) · Analytical Chemistry · doi:10.1021/ac300926h · Cited by 52 · see citing works
Self-citationSun, L., Li, Y., Yang, P., et al. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.11.050 · Cited by 46 · see citing works
Self-citationSample preparation and analytical strategies for large-scale phosphoproteomics experiments
Kanshin, E., Michnick, S. W., & Thibault, P. (2012) · Seminars in Cell and Developmental Biology · doi:10.1016/j.semcdb.2012.05.005 · Cited by 43 · see citing works
Broberg, A. (2007) · Carbohydrate Research · doi:10.1016/j.carres.2007.04.020 · Cited by 42 · see citing works
Wojcik, R., Vannatta, M. W., & Dovic̀hi, N. J. (2010) · Analytical Chemistry · doi:10.1021/ac100029u · Cited by 40 · see citing works
Self-citationSun, L., Zhu, G., Li, Y., Wojcik, R., Yang, P., & Dovic̀hi, N. J. (2012) · PROTEOMICS · doi:10.1002/pmic.201200100 · Cited by 37 · see citing works
Self-citationRadimerski, T., Mini, T., Schneider, U., et al. (2000) · Biochemistry · doi:10.1021/bi9927484 · Cited by 36 · see citing works
Sun, L., Li, Y., Champion, M. M., Zhu, G., Wojcik, R., & Dovic̀hi, N. J. (2013) · The Analyst · doi:10.1039/c3an00287j · Cited by 31 · see citing works
Self-citationMou, S., Sun, L., Wojcik, R., & Dovic̀hi, N. J. (2013) · Talanta · doi:10.1016/j.talanta.2013.08.001 · Cited by 22 · see citing works
Self-citationNicked-sleeve interface for two-dimensional capillary electrophoresis
Flaherty, R. J., Huge, B. J., Bruce, S. M., et al. (2013) · The Analyst · doi:10.1039/c3an00284e · Cited by 17 · see citing works
Чернов, И. П., Akopov, S. B., Николаев, Л. Г., & Sverdlov, E. D. (2006) · BioTechniques · doi:10.2144/000112197 · Cited by 15 · see citing works
Чернов, И. П., Timchenko, K. A., Akopov, S. B., Николаев, Л. Г., & Sverdlov, E. D. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.040 · Cited by 5 · see citing works
Detection of Low-Abundance Protein Phosphorylation by Selective 18O Labeling and Mass Spectrometry
Alghamdi, W. M., Gaskell, S. J., & Barber, J. (2012) · Analytical Chemistry · doi:10.1021/ac301038u · Cited by 4 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- [32]Olsen JV Blagoev B Gnad F Macek B Kumar C Mortensen P Mann M Cell 2006 127 635 648 17081983
Cited by
Sorted by citations
Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112 · see citing works
Capillary zone electrophoresis-mass spectrometry for bottom-up proteomics
Zhang, Z., Qu, Y., & Dovichi, N. J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.008 · Cited by 61 · see citing works
Self-citationCE–ESI‐MS for bottom‐up proteomics: Advances in separation, interfacing and applications
Heemskerk, A. A. M., Deelder, A. M., & Mayboroda, O. A. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21432 · Cited by 61 · see citing works
Zhao, Y., Riley, N. M., Sun, L., Hebert, A. S., Yan, X., Westphall, M. S., Rush, M. J. P., Zhu, G., Champion, M. M., Medie, F. M., et al. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00883 · Cited by 55 · see citing works
Self-citation
- Authors
- Mou, S., Sun, L., & Dovichi, N. J.
- Affiliations
- University of Notre Dame (US)
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, United States
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-11-05
- Volume
- 85
- Issue
- 22
- Pages
- 10692-10696
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- PMC
- PMC3873722
- OpenAlex
- W1965762619
- Cited by
- 22
- References
- 32
- Citations by year
- 2025: 1 · 2022: 1 · 2021: 1 · 2019: 2 · 2018: 5 · 2016: 2 · 2015: 3 · 2014: 6 · 2013: 1
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National institute of Health and Medical Research (R01GM096767)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Keywords
- peptide phosphorylation, phosphorylation stoichiometry, dephosphorylation, two-dimensional separation, protein phosphorylation, calibration curve, bovine serum albumin
- MeSH terms
- Alkaline Phosphatase, Animals, Cattle, Peptide Fragments, Phosphopeptides, Phosphorylation, Receptor, Insulin, Serum Albumin, Bovine, Trypsin, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization, Tandem Mass Spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review