The DOI matches its Crossref record.
Quantitative Imaging of Selenium, Copper, and Zinc in Thin Sections of Biological Tissues (Slugs−Genus Arion) Measured by Laser Ablation Inductively Coupled Plasma Mass Spectrometry
Open accessAbstract
Quantitative imaging analysis of endogenous an exogenous elements throughout entire organisms is required for studies of bioavailability, transport processes, distribution, contamination and to monitor environmental risks using indicator organisms. An imaging mass spectrometric technique using laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) was developed to analyze selenium and metal distributions in longitudinal sections (thickness, 100 microm) of entire slugs (genus arion). Slugs were fed with either a placebo or solutions containing 1000 microg mL(-1) Se. Samples (raster area, 25 mmx45 mm) were scanned together with synthetic matrix-matched standards with a focused beam of a Nd:YAG laser (wavelength, 266 nm; diameter of laser crater, 50 microm; laser power density, 3x10(9) W cm(-2)) in a large laser ablation chamber. The ablated material was transported with argon as carrier gas to the ICP ion source at a double focusing sector field ICPMS. Ion intensities of selenium (78Se+, 82Se+) were measured together with 13C+, 63Cu+, and 64Zn+ within the entire tissue section. The regression coefficient of the calibration curve was 0.998. Inhomogeneous distributions for Se but also for C, Cu, and Zn were found. Selenium was enriched in the kidney (150 microg g(-1) in Se-treated animals versus 15 microg g(-1) in the placebo-treated animal, respectively) and in the digestive gland (200 microg g(-1) versus 25 microg g(-1)). Highest Se concentrations were detected in the gut of Se-treated slugs (250 microg g(-1)), and additional Se occurred in the skin of these animals. Cu was enriched in the heart and the mucous ventral skin. Interestingly, in addition to the localization in the digestive gland, Zn was detected only in the dorsal skin but not the ventral skin. The developed analytical technique allows the quantitative imaging of selenium together with selected metals in thin sections of biological tissue with limits of detection at the submicrogram per gram range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In Situ Imaging of Metals in Cells and Tissues
McRae, R., Bagchi, P., Sumalekshmy, S., & Fahrni, C. J. (2009) · Chemical Reviews · doi:10.1021/cr900223a · Cited by 570
Awual, M. R., Hasan, M. M., Khaleque, M. A., & Sheikh, M. C. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.11.108 · Cited by 450
Bioimaging of metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS)
Becker, J. S., Zoriy, M., Matusch, A., Wu, B., Salber, D., Palm, C., & Becker, J. S. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20239 · Cited by 287
Self-citationAwual, M. R., & Hasan, M. M. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.09.086 · Cited by 258
Metadata
- Authors
- Becker, J. S., Matusch, A., Depboylu, C., Dobrowolska, J., & Zoriy, M. V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-07-11
- Volume
- 79
- Issue
- 16
- Pages
- 6074-6080
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1993892455
- Cited by
- 363
- References
- 0
- FWCI
- 11.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Imaging of Selenium, Copper, and Zinc in Thin Sections of Biological Tissues (Slugs−Genus Arion) Measured by Laser Ablation Inductively Coupled Plasma Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac0700528
- The paper
- Becker, J. S., Matusch, A., Depboylu, C., Dobrowolska, J., & Zoriy, M. V. (2007). Quantitative Imaging of Selenium, Copper, and Zinc in Thin Sections of Biological Tissues (Slugs−Genus Arion) Measured by Laser Ablation Inductively Coupled Plasma Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac0700528
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.